There have been few recent studies demonstrating a definitive association between the transmission of airborne infections and the ventilation of buildings. The severe acute respiratory syndrome (SARS) epidemic in 2003 and current concerns about the risk of an avian influenza (H5N1) pandemic, have made a review of this area timely. We searched the major literature databases between 1960 and 2005, and then screened titles and abstracts, and finally selected 40 original studies based on a set of criteria. We established a review panel comprising medical and engineering experts in the fields of microbiology, medicine, epidemiology, indoor air quality, building ventilation, etc. Most panel members had experience with research into the 2003 SARS epidemic. The panel systematically assessed 40 original studies through both individual assessment and a 2-day face-to-face consensus meeting. Ten of 40 studies reviewed were considered to be conclusive with regard to the association between building ventilation and the transmission of airborne infection. There is strong and sufficient evidence to demonstrate the association between ventilation, air movements in buildings and the transmission/spread of infectious diseases such as measles, tuberculosis, chickenpox, influenza, smallpox and SARS. There is insufficient data to specify and quantify the minimum ventilation requirements in hospitals, schools, offices, homes and isolation rooms in relation to spread of infectious diseases via the airborne route. PRACTICAL IMPLICATION: The strong and sufficient evidence of the association between ventilation, the control of airflow direction in buildings, and the transmission and spread of infectious diseases supports the use of negatively pressurized isolation rooms for patients with these diseases in hospitals, in addition to the use of other engineering control methods. However, the lack of sufficient data on the specification and quantification of the minimum ventilation requirements in hospitals, schools and offices in relation to the spread of airborne infectious diseases, suggest the existence of a knowledge gap. Our study reveals a strong need for a multidisciplinary study in investigating disease outbreaks, and the impact of indoor air environments on the spread of airborne infectious diseases.
Global phthalate ester production has increased from very low levels at the end of World War II to approximately 3.5 million metric tons/year. The aim of the present study was to investigate potential associations between persistent allergic symptoms in children, which have increased markedly in developed countries over the past three decades, and the concentration of phthalates in dust collected from their homes. This investigation is a case–control study nested within a cohort of 10,852 children. From the cohort, we selected 198 cases with persistent allergic symptoms and 202 controls without allergic symptoms. A clinical and a technical team investigated each child and her or his environment. We found higher median concentrations of butyl benzyl phthalate (BBzP) in dust among cases than among controls (0.15 vs. 0.12 mg/g dust). Analyzing the case group by symptoms showed that BBzP was associated with rhinitis (p = 0.001) and eczema (p = 0.001), whereas di(2-ethylhexyl) phthalate (DEHP) was associated with asthma (p = 0.022). Furthermore, dose–response relationships for these associations are supported by trend analyses. This study shows that phthalates, within the range of what is normally found in indoor environments, are associated with allergic symptoms in children. We believe that the different associations of symptoms for the three major phthalates—BBzP, DEHP, and di-n-butyl phthalate—can be explained by a combination of chemical physical properties and toxicologic potential. Given the phthalate exposures of children worldwide, the results from this study of Swedish children have global implications.
Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants. This review and assessment indicates that increasing ventilation rates above currently adopted standards and guidelines should result in reduced prevalence of negative health outcomes. Building operators and designers should avoid low ventilation rates unless alternative effective measures, such as source control or air cleaning, are employed to limit indoor pollutant levels.
Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m 3 ) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h ª1 . The temperature of 22 aeC, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (PϽ0.002) and the intensity of odour (PϽ0.02), and increased the perceived freshness of air (PϽ0.05). It also decreased the sensation of dryness of mouth and throat (PϽ0.0006), eased difficulty in thinking clearly (PϽ0.001) and made subjects feel generally better (PϽ0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (PϽ0.03). For each twofold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.Key words Perceived air quality; IAQ; SBS symptoms; Productivity; Ventilation; Outdoor air change rate; Office. Practical ImplicationsGood indoor air quality is beneficial for health, comfort and productivity. It is therefore advisable to ventilate indoor environments at rates above the minimum levels prescribed in present standards and guidelines. Reducing costs and conserving energy by maintaining modest levels of ventilation can easily result in a net loss if productivity is decreased. Increasing ventilation rates above minimum levels can raise productivity and will, in many cases, pay for itself while decreasing the intensity of SBS symptoms and improving perceived air quality. Intelligent use of energy recovery can often minimize energy consumption caused by increased ventilation. As an alternative or supplement to increased ventilation, it will often be beneficial for indoor air quality to eliminate or reduce sources of indoor air pollution or to supply ventilation air close to the breathing zone of the occupants.
Several epidemiological investigations concerning indoor environments have indicated that "dampness" in buildings is associated to health effects such as respiratory symptoms, asthma and allergy. The aim of the present interdisciplinary review is to evaluate this association as shown in the epidemiological literature. A literature search identified 590 peer-reviewed articles of which 61 have been the foundation for this review. The review shows that "dampness" in buildings appears to increase the risk for health effects in the airways, such as cough, wheeze and asthma. Relative risks are in the range of OR 1.4-2.2. There also seems to be an association between "dampness" and other symptoms such as tiredness, headache and airways infections. It is concluded that the evidence for a causal association between "dampness" and health effects is strong. However, the mechanisms are unknown. Several definitions of dampness have been used in the studies, but all seems to be associated with health problems. Sensitisation to mites may be one but obviously not the only mechanism. Even if the mechanisms are unknown, there is sufficient evidence to take preventive measures against dampness in buildings.
In a recent study of 198 Swedish children with persistent allergic symptoms and 202 controls without such symptoms, we reported associations between the symptoms and the concentrations of n-butyl benzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) in dust taken from the childrens’ bedrooms. In the present study we examined associations between the concentrations of different phthalate esters in the dust from these bedrooms and various characteristics of the home. The study focused on BBzP and DEHP because these were the phthalates associated with health complaints. Associations have been examined using parametric and nonparametric tests as well as multiple logistic regression. For both BBzP and DEHP, we found associations between their dust concentrations and the amount of polyvinyl chloride (PVC) used as flooring and wall material in the home. Furthermore, high concentrations of BBzP (above median) were associated with self-reported water leakage in the home, and high concentrations of DEHP were associated with buildings constructed before 1960. Other associations, as well as absence of associations, are reported. Both BBzP and DEHP were found in buildings with neither PVC flooring nor wall covering, consistent with the numerous additional plasticized materials that are anticipated to be present in a typical home. The building characteristics examined in this study cannot serve as complete proxies for these quite varied sources. However, the associations reported here can help identify homes where phthalate concentrations are likely to be elevated and can aid in developing mitigation strategies.
The review group concluded that breastfeeding seems to protect from the development of atopic disease. The effect appears even stronger in children with atopic heredity. If breast milk is unavailable or insufficient, extensively hydrolysed formulas are preferable to unhydrolysed or partially hydrolysed formulas in terms of the risk of some atopic manifestations.
Indoor air quality plays a major role with regard to public health. The main problems are in the developing countries with the indoor burning of biomass for cooking and heating. The solution is a stove with a chimney. In developed regions, good ventilation, getting rid of "dampness" problems, and adequate testing of new building materials would reduce morbidity and mortality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.