A variety of asynchronies between the patient’s respiratory efforts and the programed ventilatory settings have been categorized. Reverse trigger is described as an inspiratory effort occurring after a ventilator-initiated breath and may represent a form of respiratory entrainment. In other words, the ventilator triggers muscular efforts. It often appears in a repetitive, stereotyped pattern. It occurs often in mechanically ventilated patients at risk of injury, might be underrecognized at the bedside and may has adverse effects on oxygenation and ventilation, as well as potentially increasing lung injury. We can phenotype these events using the Campbell diagram (pressure–volume loop) by differentiating their occurrence during inspiration and expiration. Reverse trigger with sufficient inspiratory effort and duration can result in an additional ventilator-delivered stacked breath, which can cause large tidal volumes and increased transpulmonary pressure. Keywords: Asynchrony, ventilator, reverse trigger, entrainment, lung injury, phenotype.
Patient-ventilator asynchrony/dysynchrony is a mismatch between the patient and the ventilator's delivered breaths and the ability of the ventilator to meet the patient demands. Any factor that alters the harmony between these two components produces asynchrony, which can cause discomfort and an increase in the patient's work of breathing. Delayed cycling occurs when the neural time is less than the mechanical time of the ventilator. Keywords: asynchrony, ventilator, delayed cycling, work of breathing, neural time, mechanical time.
Mechanical ventilation supports the work of breathing, improves gas exchange, and unloads the respiratory muscles, all of which require good synchronization between the patient and the ventilator. Asynchronies occur when the ventilator’s breath delivery does not match the patient’s neural ventilatory pattern or is inadequate to meet the patient’s flow demand. Patient–ventilator asynchrony can be easily detected by observing the patients in those extreme situations in which they fight the ventilator; nevertheless, the vast majority of asynchronies occur without major clinical signs and go undetected or corrected without measuring patient's respiratory effort (either esophageal pressure or electrical activity of the diaphragm). Synchrony problems are common, occurring in perhaps as many as 25% of patients receiving invasive ventilation and up to 80% of patients receiving noninvasive ventilation. In this concise review, we describe work shifting and double triggering asynchronies. Keywords: Patient-ventilator asynchronies, work shifting, double triggering
Mechanical ventilation is a lifesaving treatment but can be associated with some complications such as ventilator-induced lung injury, ventilator associated pneumonia or ventilation induced diaphragm dysfunction. Although partial ventilatory support is preferred to limit some of the complications associated with controlled mechanical ventilation, there could be some problems like asynchrony between the patient and the ventilator. Asynchronies occur when the ventilator’s breath delivery does not match the patient’s ventilatory pattern or is inadequate to meet their flow demand. Asynchronies can lead to patient’s discomfort, prolong mechanical ventilation, intensive care unit stay and mortality. Early cycling occurs when the patient’s neural inspiratory time is longer than the inspiratory time imposed by the ventilator. It is a common cause of double trigger.
Mechanical ventilation is a common issue in critically ill patients. It is a lifesaving treatment but also can cause some complications. Patient-ventilator asynchronies are frequent but are often underdiagnosed and they are a serious problem that is associated with worse clinical outcomes. Asynchrony occurs when there is a mismatch between the ventilator setting and the patient´s demand or breath delivery timing. There are a variety of asynchronies between the patient’s respiratory efforts and the programed ventilatory setting. Ineffective effort is a kind of asynchrony of the trigger variable. It occurs when the patient’s inspiratory effort fails to trigger a ventilator breath. Ineffective inspiratory efforts are a great problem in patient-ventilator interaction, and they are the most common type of asynchrony.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.