Non-cardiac surgery in a high-risk patient with severe mitral stenosis (MS) and severe pulmonary hypertension (PH) presents a significant anesthetic challenge. Guidelines recommend using advanced hemodynamic monitors for specific cardiovascular goals. The gold standard for intraoperative monitoring in these cases is the pulmonary artery catheter (PAC) and transesophageal echocardiography (TEE). This case discusses the successful management of a severe MS patient undergoing cystoprostatectomy using a minimally invasive cardiovascular monitor (MICM) incorporating several hemodynamic parameters.
Kennedy's disease (KD), also known as spinal and bulbar muscular atrophy (SBMA), is a rare, X-linked recessive androgen receptor gene mutation affecting approximately one in 40,000 males. A prominent anesthetic concern in patients with KD is their ability to maintain a patent airway following general anesthesia. We present the case of a 61-year-old man with a history of KD presenting for a left thigh sarcoma excision. The patient received a general anesthetic with endotracheal tube placement, was extubated in the operating room upon completion of the surgery, and had an uneventful post-operative course.
In medicine, the search for a clear answer can at times be elusive. However, this does not necessarily preclude the administration of intelligent and thoughtful therapeutic treatments. Here, we describe a complicated emergent event of severe hypotension and near-arrest that occurred in the operating room in a young, healthy woman undergoing outpatient thyroid surgery. We detail the situation as it presented in the operating room and the measures taken to rule out potential life-threatening diagnoses and develop a thoughtful treatment plan. We further describe the evidence for and against the two remaining diagnostic possibilities: anaphylaxis versus acute pulmonary embolism.
Statin-induced necrotizing autoimmune myopathy (SINAM) is a rare side effect in people who are taking a class of drugs called statins. Patients with SINAM will present with subacute severe symmetric proximal muscle weakness. In contrast to more common myopathies, SINAM may not spontaneously resolve with statin discontinuation. These patients may require long-term immunotherapy to limit further disease progression. In this case study, we report a 74-year-old female with SINAM who presented for radical excision of a right upper back melanoma and sentinel lymph node biopsy at an outpatient facility. An anesthetic plan was crafted with the use of a supraglottic airway device without neuromuscular blockade.
Background
Epidural catheters are routinely placed for many surgical procedures and to treat various pain conditions. Known complications arising from epidural catheter equipment malfunction include epidural pump failure, epidural catheter shearing, epidural catheter connector failure, epidural filter connector cracking, and loss-of-resistance syringe malfunction. Practitioners need to be aware of these potentially dangerous complications and take measures to mitigate the chances of causing significant patient harm. We report on the complete breakage of an epidural filter connector during epidural bolus administration of local anesthetic by hand with a syringe.
Case presentation
A B. Braun Perifix® epidural catheter was placed in a 73-year-old male scheduled for radical prostatectomy. During the operation, a continuous infusion of local anesthetic was administered through the epidural catheter in addition to general endotracheal anesthesia. At the conclusion of surgery and after extubation, the patient endorsed incisional pain. The epidural filter connector broke in half as a bolus of local anesthetic was administered by hand with a syringe. The local anesthetic sprayed widely throughout the room as the fragmented epidural filter connector became a projectile object that recoiled and struck the patient.
Conclusions
This incident placed the patient and surrounding healthcare providers at substantial risk for injury and infection from the fractured epidural filter connector becoming a projectile object and from the local anesthetic spray. The most plausible cause of this event was from a large amount of pressure being applied to the filter connector. This may have occurred by excessive force being applied by hand to the syringe, by the presence of a clogged filter, or by the catheter being kinked or blocked proximal to the filter. Being aware of this deleterious complication and potentially modifying existing epidural bolus techniques, such as using smaller syringes with less applied force and checking all epidural components vigilantly prior to and during bolus administration, can help anesthesia providers deliver the safest possible care to patients with epidural catheters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.