Primary signet ring cell carcinoma of urinary bladder is a rare type of bladder tumor and carries a very high mortality rate. It may have a clinical presentation similar to common diseases like benign prostatic hypertrophy and the management options are extremely limited. We report a case of 58-year-old Caucasian male who presented with a 5 month history of increased frequency of urination, nocturia and weight loss without any fever or hematuria. He was found to have an increased creatinine of 2.8 mg/dl and a prostate specific antigen level of 0.18 ng/ml. His azotemia was thought to be secondary to BPH. A Foley catheter was initially placed with a plan for outpatient follow up. On removal of the catheter his problems persisted and he returned to the hospital. Diagnostic work up including abdominal ultrasonography, computed tomography scan, retrograde pyelogram, cystography and cystoscopic biopsies revealed the diagnosis of primary signet ring cell carcinoma of urinary bladder. Although cystectomy was planned, our patient passed away before this could be done.
BACKGROUND
Little is known regarding the effect of hemorrhagic shock on the diagnosis and treatment of tension pneumothorax (tPTX). Recently, the Tactical Combat Casualty Care guidelines included the 10-gauge angiocatheter (10-g AC) as an acceptable alternative to the 14-g AC. This study sought to compare these two devices for decompression of tPTX and rescue from tension-induced pulseless electric activity (tPEA) in the setting of a concomitant 30% estimated blood volume hemorrhage.
METHODS
Following a controlled hemorrhage, carbon dioxide was insufflated into the chest to induce either tPTX or tPEA. Tension pneumothorax was defined as a reduction in cardiac output by 50%, and tPEA was defined as a loss of arterial waveform with mean arterial pressure less than 20 mm Hg. The affected hemithorax was decompressed using a randomized 14-g AC or 10-g AC while a persistent air leak was maintained after decompression. Successful rescue from tPTX was defined as 80% recovery of baseline systolic blood pressure, while successful return of spontaneous circulation following tPEA was defined as a mean arterial pressure greater than 20 mm Hg. Primary outcome was success of device.
RESULTS
Eighty tPTX and 50 tPEA events were conducted in 38 adult Yorkshire swine. There were no significant differences in the baseline characteristics between animals or devices. In the tPTX model, the 10-g AC successfully rescued 90% of events, while 14-g AC rescued 80% of events (p = 0.350). In the tPEA model, the 10-g AC rescued 87% of events while the 14 AC rescued only 48% of events (p = 0.006).
CONCLUSION
The 10-g AC was vastly superior to the 14-g AC for return of spontaneous circulation following tPEA in the setting of 30% hemorrhage. These findings further support the importance of larger caliber devices that facilitate rapid recovery from tPTX, particularly in the setting of polytrauma.
LEVEL OF EVIDENCE
Therapeutic, level II.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.