The role of long chains in shear-mediated crystallization was studied by in situ rheo-optical measurements and ex situ microscopic observations. To elucidate the effects of long chains, we prepared model blends in which fractionated isotactic polypropylene (iPP) (denoted L-PP) with high molecular weight (MW) and narrow molecular weight distribution was blended with a metallocene iPP (Base-PP) with lower molecular weight. The concentration of L-PP (c) was varied ranging from 0 to twice the concentration (c*) at which L-PP coils overlap. The crystallization of all blends after cessation of transient shearing was accelerated, while the quiescent crystallization kinetics were not affected by the addition of L-PP. A distinctive change in the development of birefringence after shearing was observed when the wall shear stress (σ w) exceeded a critical value (σ*). Below σ*, irrespective of c, the birefringence after transient shearing increased gradually, reaching a small value at the end of crystallization. Above σ*, a brief interval of shear induced highly oriented growth, manifested in the birefringence after cessation of flow and growing stronger and reaching a large value as crystallization proceeded. Further, the rate of growth of the birefringence exhibited a strong, nonlinear c dependence. The morphology of the skin layer showed a shish kebab type structure observed by TEM for samples subjected to stresses above σ*. The number density and thickness of shish were affected by c and changed drastically at c near the overlap concentration of the long chains. This indicates that the role of long chains in shear-induced oriented crystallization is cooperative (rather than a single chain effect), enhanced by long chain-long chain overlap.
The seminal ideas of de Gennes and Doi and Edwards have provided the theoretical framework for much of the recent effort to model the rheological behavior of entangled polymer melts and solutions. Recent theoretical work has incorporated a number of important additions to the basic Doi-Edwards theory, including an explicit description of chain stretch and additional relaxation mechanisms such as contour length fluctuations (CLF) and convective constraint release (CCR). However, very little quantitative data has been published on the rheological behavior of entangled systems in strong flows. Hence, a comprehensive examination of the theoretical developments has not been possible. The experiments described in this paper use the filament stretching rheometer to obtain transient extensional stress growth data and steady state uniaxial extensional viscosity data for a number of entangled, narrow molecular weight distribution polystyrene solutions in the strain-rate regime characterized by a significant degree of both chain alignment and stretch. These results are then compared with theoretical predictions for a number of the current generation of reptation-based models, including mechanisms for chain stretching, contour length fluctuations, and convective constraint release. These comparisons demonstrate that when the model parameters are properly obtained from linear viscoelastic measurements, the recent model due to Mead, Larson, and Doi (Macromolecules 1998, 31, 7895) provides quantitative predictions for this class of flows for solutions spanning the complete range from very lightly to highly entangled solutions.
Limited clinical data speak to the potential of bioresorbable scaffolds as a new therapy, and future studies will prove critical to inspiring a fourth revolution in PCI.
Linear and nonlinear viscoelastic measurements were utilized to probe transient morphological changes in a melt-blended polypropylene-clay nanocomposite containing 3 wt % organically modified montmorillonite clay, 10 wt % maleic anhydride functionalized polypropylene (1% maleic anhydride content), and 87 wt % polypropylene homopolymer. Steady shear rate sweeps show that the viscosity decreases monotonically with shear rate, characteristic of a mechanically percolated material with a yield stress. Subsequent sweeps following annealing of up to 2 h show that the viscosity at low shear rates remains substantially lower than the initial sweep, indicative of slow or arrested organoclay disorientation. In startup of shear flow, as-processed and presheared nanocomposite samples both exhibit increasing viscosity overshoots with annealing time for up to 6 h, although the overshoots for the presheared samples remain uniformly smaller than those of the as-processed material. Similarly, small-amplitude oscillatory shear experiments on as-processed and presheared samples also reveal that the storage modulus and complex viscosity increase logarithmically with time, while the loss tangent declines steadily. Both sets of data point to increasingly solidlike rheology over time, a phenomenon that is discussed in the context of soft glassy dynamics.
Inappropriate blood coagulation plays a central role in the onset of myocardial infarction, stroke, pulmonary embolism, and other thrombotic disorders. The ability to screen for an increased propensity to clot could prevent the onset of such events by appropriately identifying those at risk and enabling prophylactic treatment. Similarly, the ability to characterize the mechanical properties of clots in vivo might improve patient outcomes by better informing treatment strategies. We have developed a technique called sonorheometry. Unlike existing methods, sonorheometry is able to assess mechanical properties of coagulation with minimal disturbance to the delicate structure of a forming thrombus. Sonorheometry uses acoustic radiation force to produce small, localized displacements within the sample. Time delay estimation is performed on returned ultrasound echoes to determine sample deformation. Mechanical modeling and parametric fitting to experimental data yield maps of mechanical properties. Sonorheometry is well suited to both in vitro and in vivo applications. A control experiment was performed to verify that sonorheometry provides mechanical characterization in agreement with that from a conventional rheometer. We also examined thrombosis in blood samples taken from four subjects. This data suggests that sonorheometry may offer a novel and valuable method for assessing the thrombogenicity of blood samples.
This work seeks to optimize the twin‐screw compounding of polymer‐clay nanocomposites (PCNs). Proportional amounts (3:1) of maleic anhydride functionalized polypropylene compatibilizer (PP‐g‐MA) and organically modified montmorillonite clay at clay loadings of 1, 3, and 5 wt% were melt‐blended with a polypropylene (PP) homopolymer using a Leistritz Micro 27 twin‐screw extruder. Three melt‐blending approaches were pursued: (1) a masterbatch of PP‐g‐MA and organoclay were blended in one pass followed by dilution with the PP resin in a second pass; (2) all three components were processed in a single pass; and (3) uncompatibilized PP and organoclay were processed twice. Both corotation and counterrotation operation were utilized to investigate the effect of screw rotation mode and sequence on organoclay exfoliation and dispersion. X‐ray diffraction was employed to characterize basal spacing; however, since rheology is known to be highly sensitive to mesoscale organoclay structure, it is an ideal tool to examine the relationship between the various processing methods and exfoliation and dispersion. A holistic analysis of rheological data demonstrates the efficacy of the masterbatch approach, particularly when compatibilizer and organoclay are blended in counterrotating mode followed by dilution with matrix polymer in corotating mode. POLYM. ENG. SCI., 47:898–911, 2007. © 2007 Society of Plastics Engineers
Poly(L-lactide) (PLLA) is the structural material of the first clinically approved bioresorbable vascular scaffold (BVS), a promising alternative to permanent metal stents for treatment of coronary heart disease. BVSs are transient implants that support the occluded artery for 6 mo and are completely resorbed in 2 y. Clinical trials of BVSs report restoration of arterial vasomotion and elimination of serious complications such as late stent thrombosis. It is remarkable that a scaffold made from PLLA, known as a brittle polymer, does not fracture when crimped onto a balloon catheter or during deployment in the artery. We used X-ray microdiffraction to discover how PLLA acquired ductile character and found that the crimping process creates localized regions of extreme anisotropy; PLLA chains in the scaffold change orientation from the hoop direction to the radial direction on micrometer-scale distances. This multiplicity of morphologies in the crimped scaffold works in tandem to enable a low-stress response during deployment, which avoids fracture of the PLLA hoops and leaves them with the strength needed to support the artery. Thus, the transformations of the semicrystalline PLLA microstructure during crimping explain the unexpected strength and ductility of the current BVS and point the way to thinner resorbable scaffolds in the future. structural transformation | ductility | poly (L-lactide) | coronary heart disease | microdiffraction C ardiovascular disease (CVD) claims over 15 million lives per year-more lives than communicable, maternal, neonatal, and nutritional disorders combined and more than twice the number of deaths due to all cancers (1). Coronary heart disease (CHD), the narrowing of coronary arteries due to the deposition of plaque, accounts for nearly 50% of all CVD deaths (1). To restore blood flow, most patients receive minimally invasive balloon angioplasty followed by stent implantation (1 million in 2008 in the United States) (2). Stents are metal mesh tubes that are delivered to the target lesion while they are crimped onto a balloon. Once they are positioned at the lesion, inflation of the balloon compresses the plaque against the vessel wall and deploys the stent to provide support at the enlarged diameter after the balloon is deflated and withdrawn. Metal stents are permanent, and their stiffness prohibits vasomotion and dilation (3, 4). Further, they present a lifelong risk of late stent thrombosis (3-6). A new technology is poised to displace metal stents: bioresorbable vascular scaffolds (BVS), which have been deemed the "fourth revolution" in percutaneous coronary intervention (7,8).The goal of tissue scaffolds is to restore the healthy state of the tissue, rather than merely ameliorating the diseased state (9-11). Poly(L-lactide) (PLLA) was selected as the material for BVS because its semicrystalline structure gives it adequate radial strength [>300 mm Hg (12)], and it degrades into products that are metabolized by the human body (13-16). Clinically, bioresorption of PLLA vascular sca...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.