Edited by: Philip J. Atherton New Findings r What is the central question of this study?Is the near-infrared spectroscopy-derived measure of tissue oxygen saturation (S tO 2 ) reperfusion slope sensitive to a range of ischaemic conditions, and do differences exist between trained and untrained individuals? r What is the main finding and its importance?The S tO 2 reperfusion rate is sensitive to different occlusion durations, and changes in the reperfusion slope in response to a variety of ischaemic challenges can be used to detect differences between two groups. These data indicate that near-infrared spectroscopy-derived measures of S tO 2 , specifically the reperfusion slope following a vascular occlusion, can be used as a sensitive measure of vascular responsiveness.The reperfusion rate of near-infrared spectroscopy-derived measures of tissue oxygen saturation (S tO 2 ) represents vascular responsiveness. This study examined whether the reperfusion slope of S tO 2 is sensitive to different ischaemic conditions (i.e. a dose-response relationship) and whether differences exist between two groups of different fitness levels. Nine healthy trained (T; age 25 ± 3 years; maximal oxygen uptake 63.4 ± 6.7 ml kg −1 min −1 ) and nine healthy untrained men (UT; age 21 ± 1 years; maximal oxygen uptake 46.6 ± 2.5 ml kg −1 min −1 ) performed a series of vascular occlusion tests of different durations (30 s, 1, 2, 3 and 5 min), each separated by 30 min. The S tO 2 was measured over the tibialis anterior using near-infrared spectroscopy, with the S tO 2 reperfusion slope calculated as the upslope during 10 s following cuff release. The reperfusion slope was steeper in T compared with UT at all occlusion durations (P < 0.05). For the T group, the reperfusion slopes for 30 s and 1 min occlusions were less than for all longer durations (P < 0.05). The reperfusion slope following 2 min occlusion was similar to that for 3 min (P > 0.05), but both were less steep than for 5 min of occlusion. In UT, the reperfusion slope at 30 s was smaller than for all longer occlusion durations (P < 0.05), and 1 min occlusion resulted in a reperfusion slope that was less steep than following 2 and 3 min (P < 0.05), albeit not different from 5 min (P > 0.05). The present study demonstrated that the reperfusion rate of S tO 2 is sensitive to different occlusion durations, and that changes in the reperfusion rate in response to a variety of ischaemic challenges can be used to detect differences in vascular responsiveness between trained and untrained groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.