Installing cable above a suspended ceiling in the presence of asbestos-containing fireproofing is an example of an activity that may disturb in-place asbestos and associated dust and debris. Two simulations of cable installation were conducted in a room of an unoccupied school to test the extent of such disturbance and resulting elevations in airborne asbestos. Average airborne asbestos concentrations in the room increased over 500-fold during the simulations, with several samples exceeding 50 structures per cubic centimeter (s/cm3), as measured by transmission electron microscopy (TEM) with an indirect preparation technique. Elevated concentrations persisted during a subsequent cleaning of horizontal surfaces in the room and for several hours thereafter. Personal samples collected on the cable installers yielded TEM measurements averaging approximately 68 s/cm3 for the two simulations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.