Background: There has been no direct comparison of all existing plates dedicated for fracture osteosynthesis of mandibular condyle base until now. The aim of the study was to test mechanically all available designs of titanium plates on the market on polyurethane mandibles using an individually designed clamping system. Methods: Forces required for a 1 mm displacement of fixed fracture and incidents of screw loosening were recorded. Results indicated the best mechanical plates among all existing designs available. Results: It has occured that some of osseofixation plates should not be used any more, whereas some shape of the single plates are similar shape to two single plates shape are regarded as the best osseofixation method for condyle base fracture. Conclusion: General observation is the bigger plate and more screws, the better rigid stable osteosynthesis of mandibular condyle base. 4 plates of current designs of total 30 tested series can be recommended for open rigid internal fixation of fractures of the base of the mandibular condyle. The rest of 26 existing plates should not be used in condylar base fractures.
Background: In the literature no information about plates for the high-neck mandibular condylar osteosynthesis could be found despite that 30 plate designs have been published. The main course consider the basal condylar or diacapitular fractures. The aim of the study was to test mechanically all available designs (only 4 of 30 was proper) on polyurethane mandibles using an individually designed clamping system. Methods: Forces required for a 1 mm displacement of fixed fracture fragments and incidents of screw loosening were recorded. Results: It has occured that dedicated plates for fixation are much weaker than set of two straight plates (p < 0.0001). General observation is the bigger plate and more screws, the better rigid stable osteosynthesis of mandibular condyle, however, there are limitations in plates design for high-neck fractures resulted in restricted operation field. Conclusion: Double straight plates occured to be the best mechanical fixation for high-neck fractures of the mandibular condyle. Maybe other existing plates could be used but only after prebending or that fracture required novel dedicated plates design.
Background: In the literature, no information on plates for low-neck mandibular condylar osteosynthesis can be found, despite the fact that 30 plate designs have already been published. The aim of this study was to compare any dedicated plates for possible use in low-neck condylar fracture osteosynthesis. Methods: The force required for 1-mm displacement of the fixed fracture fragments and incidents of screw loosening were recorded on polyurethane mandibles among 16 designs of titanium plates fixed by 6-mm screws in a 2.0 system. Results: Double-straight plate fixation was the mechanical gold standard (15.2 ± 3.5 N), followed by A-shape Condylar Plates (14.9 ± 2.1 N), X-shape Condylar Plates (14.2 ± 1.3 N) and Auto Repositioning Plates (11.8 ± 2.4 N). Screw loosening was uncommon, as a minimum of three screws were placed into the condylar part. Fewer screws were lost from the ramus part of the fixation if the plate was attached to the condylar part by three screws. Often, the stability of the ramus screws was lost when there were only two fixing screws in the condyle (p < 0.001). Conclusions: It is advisable to consider the mechanical advantages as one decides which plate to choose for open rigid internal fixation in low-neck condylar fractures, or to only be aware of the significant differences in mobility within the fracture line after fixation with different dedicated plates.
In the surgical treatment of the most common fracture of the mandible, which is a fracture of the condylar base, a great choice of different plate shapes is observed. The aim of this study was to determine which shape gives the greatest fixation stiffness. To ensure homogeneity in comparison, tests were performed on polyurethane models divided at the level of the condylar base fracture and each were fixed with 51 plates. The plates were cut from a 1 mm thick grade 23 titanium sheet. The models were then loaded and the force required for 1 mm of fracture displacement was recorded. It was noted that in addition to osteosynthesis from two simple plates, there were also two dedicated single plates with similar rigidity. Among the large number of described designs of plates, there is considerable variation in terms of the stability of the fixation performed with them. The proposed Mechanical Excellence Factor allows a pre-evaluation of the expected rigidity of fixation with a given plate shape without the need for a loading experiment. The authors expect this to be helpful for surgeons in the application of relevant plates, as well for inventors of new plates for the osteosynthesis of basal fractures in mandibular condyle.
Background: The mandible is the most injured part of the facial skeleton, and 25–40% of mandibular fractures involve the condyle process. The aim of this study is to answer the question of the relationship between screw pullout and/or plate fracture during osteosynthesis. Methods: We tested polyurethane models of mandibles whose condylar process was cut (simulating a fracture) and fused using plates and screws. Results: A total of 672 plates were tested. A total of 25.6% of them were fractured during the test, with most being fractures of the base of the condyle. More screws (81.97%) are pulled out from the ramus than from the condyle—69.15%. Conclusions: The gold standard in the osteosynthesis of condylar fractures is two straight plates. Other than these, there is no one-size-fits-all plate for every type of fracture. Plates fixed with fewer screws (smaller plates used in higher-lying fractures) are more likely to result in screw pullout. On the other hand, in plates fixed with more screws, plate fracture is more common.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.