The aim of this study was to evaluate and compare the diagnostic accuracy, the inter-rater agreement and raters’ certainty of cone beam computed tomography (CBCT) and radiography for the detection of scaphoid fractures. Our hypothesis is that the CBCT has a higher diagnostic accuracy for scaphoid fractures than radiography. We retrospectively analysed patients who underwent both radiography and CBCT examinations within 4 days to rule out a scaphoid fracture over a 2-year period in our institution. 4 blinded radiologists and orthopaedic surgeons independently rated the images regarding the presence of a scaphoid fracture. The reference standard was evaluated by two radiologists in a consensus reading. Inter-rater correlation was evaluated, pooled sensitivity, specificity, positive and negative predictive values were calculated and compared. 102 patients met the inclusion criteria. 52% of them had a scaphoid fracture. The inter-rater correlation was higher in the CBCT compared to radiography (P < 0.001). Sensitivity, specificity, positive and negative predictive values were higher for CBCT than for radiography (P < 0.019). Observers’ fracture classifications showed a higher correlation with the reference standard in the CBCT. Observers’ certainty for fracture detection and classification were higher in the CBCT. CBCT shows a higher diagnostic accuracy for scaphoid fractures than radiography.
PURPOSE Image analysis is one of the most promising applications of artificial intelligence (AI) in health care, potentially improving prediction, diagnosis, and treatment of diseases. Although scientific advances in this area critically depend on the accessibility of large-volume and high-quality data, sharing data between institutions faces various ethical and legal constraints as well as organizational and technical obstacles. METHODS The Joint Imaging Platform (JIP) of the German Cancer Consortium (DKTK) addresses these issues by providing federated data analysis technology in a secure and compliant way. Using the JIP, medical image data remain in the originator institutions, but analysis and AI algorithms are shared and jointly used. Common standards and interfaces to local systems ensure permanent data sovereignty of participating institutions. RESULTS The JIP is established in the radiology and nuclear medicine departments of 10 university hospitals in Germany (DKTK partner sites). In multiple complementary use cases, we show that the platform fulfills all relevant requirements to serve as a foundation for multicenter medical imaging trials and research on large cohorts, including the harmonization and integration of data, interactive analysis, automatic analysis, federated machine learning, and extensibility and maintenance processes, which are elementary for the sustainability of such a platform. CONCLUSION The results demonstrate the feasibility of using the JIP as a federated data analytics platform in heterogeneous clinical information technology and software landscapes, solving an important bottleneck for the application of AI to large-scale clinical imaging data.
• Subjectively, CBCT remains inferior to MSCT in depicting most structures. • Similar diagnostic validity for CBCT and MSCT imaging of distal radius fractures. • CBCT is a possible alternative to MSCT in musculoskeletal imaging. • Visual grading characteristics (VGC) analysis proves useful in analyzing visual grading scales.
Carcinosarcomas are rare biphasic neoplasms with distinct malignant epithelial and mesenchymal components. Most commonly, carcinosarcomas arise in the uterus as malignant mixed müllerian tumors, but also infrequently appear in other organs such as the ovaries and breast, the prostate and urinary tract, the lungs, or in the gastrointestinal system, among others. Pancreatic carcinosarcomas are exceedingly rare; only a few cases are reported in the English literature. Their pathogenesis remains to be fully clarified. We present here the case of a pancreatic carcinosarcoma with evidence for monoclonality via determination of Kras mutational status after microdissection and suggest a common origin of the 2 tumor components. Comprehensive review of the available literature allows the conclusion that most pancreatic carcinosarcomas appear to be of monoclonal origin and seem to have arisen from a carcinoma via metaplastic transformation of 1 part or subclone of the tumor, probably by epithelial-mesenchymal transition. All reported patients were treated with surgery. Adjuvant therapy, if administered, consisted predominantly of gemcitabine. Prognosis for this neoplasm occurs to be similar or even worse compared with classic pancreatic ductal adenocarcinoma. Despite the lack of evidence-based recommendations for its treatment, resection should be performed, if possible.
Ocular sonography identifies SAH-related preretinal and vitreous hemorrhages with high accuracy and is superior to standard head CT. It may be considered as new and useful bedside diagnostic tool for routine clinical care of patients with SAH.
We compared a mobile FPCT and a 320-row MDCT by using the same radiation dose for scans. We found the spatial resolution to be higher in the FPCT. Hounsfield units were more accurate and homogeneity and contrast resolution were better in MDCT. The MDCT was also less prone to artifacts from thick Kirschner wires but showed comparably more artifacts around thin wires.
Purpose: Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand.
Materials and Methods: Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose.
Results: The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT.
Conclusion: Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.
Key points:
??Low dose examinations of the hand are feasible in CBCT and MDCT.
??In default settings CBCT has a lower dose than MDCT.
??MDCT enables a good image quality at a lower dose than CBCT.
Citation Format:
??Neubauer J, Neubauer C, Gerstmair A et?al. Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in?Examinations of the Hand. Fortschr R?ntgenstr 2016; 188: 488???493
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.