PPM is a common postprocedure requirement after TAVI. The absence of prior valve surgery, the implantation of Medtronic CoreValve™ prosthesis, and the presence of a porcelain aorta were independently associated with PPM after TAVI.
BackgroundTakotsubo syndrome (TTS) is characterized by a transient left and/or right ventricular dysfunction as a consequence of a distinctive pattern of regional wall motion abnormalities. However, a systematic evaluation of the left atrial (LA) function in patients with TTS is lacking. The aim of the present study was therefore to comprehensively assess LA performance indexes and function in patients with TTS.MethodsWe compared LA function assessed by volumetric indexes derived from fractional volume changes in cardiovascular magnetic resonance (CMR) between 125 TTS patients and 125 patients with anterior ST-segment elevation myocardial infarction (STEMI). Furthermore, recovery of LA performance was evaluated in a subgroup of 20 TTS patients with follow-up CMR data.ResultsPatients with TTS demonstrated a significantly lower total LA emptying fraction (EF) [44% (interquartile range (IQR) 34–53%) versus 51% (IQR 42–56%); p < 0.01], passive LA-EF [21% (IQR 14–30%) versus 24% (IQR 20–29%); p = 0.03] and active LA-EF [29% (IQR 20–38%) versus 35% (28–42%); p < 0.01] compared to patients with anterior STEMI. Among the 20 TTS patients with serial CMR data, the total LA-EF significantly improved from 42% (IQR 29–48%) at the acute stage to 51% (IQR 46–59%) at follow-up (p < 0.01). Similarly, active LA-EF (p < 0.01) and passive LA-EF (p = 0.02) improved significantly as well.ConclusionCompared to anterior STEMI, TTS patients demonstrated a significantly decreased LA function during the acute/subacute phase of the disease. However, impairment of LA performance seems to be transient in TTS with recovery during follow-up.
Our results of a real-world registry suggest that the extent of aortic valve calcification does not influence the success or procedural outcome significantly.
Aims
Patients with heart failure and severe mitral regurgitation (MR) have a poor prognosis and carry an increased risk for ventricular arrhythmias. The present study evaluates the impact of transcatheter mitral valve repair using the MitraClip on the potential reduction of ventricular arrhythmias.
Methods and results
Patients undergoing MitraClip implantation were prospectively enrolled into the present study and received 24 h Holter ECG assessment prior to and 6 months after the procedure. In addition, left ventricular dimensions and function were assessed at baseline and follow-up. A total of 50 patients with mainly functional MR (82%) were included. Non-sustained or sustained ventricular tachycardia (nsVT and/or sVT) occurred in 32% of patients and was reduced to 14% at follow-up (P = 0.01). Also, premature ventricular complex (PVC) burden ≥5% decreased from 16% to 4% (P = 0.04). Patients with persistent (n = 6) or new (n = 1) nsVT and/or sVT at follow-up showed a significant decrease in left ventricular ejection fraction from 38% (interquartile range 26–45%) to 33% (interquartile range 22–44%; P = 0.03).
Conclusions
In this prospective study, transcatheter mitral valve repair using MitraClip was associated with a reduced prevalence of ventricular arrhythmias. The subset of patients with persistent or new ventricular arrhythmias after MitraClip implantation showed progression of left ventricular dysfunction.
Objective: Procedural characteristics, including stent design, may influence the outcome of carotid artery stenting (CAS). A thorough comparison of the effect of stent design on outcome of CAS is thus warranted to allow for optimal evidence-based clinical decision making. This study sought to evaluate the effect of stent design on clinical and radiological outcomes of CAS.Methods: A systematic search was conducted in MEDLINE, Embase, and Cochrane databases in May 2018. Included were articles reporting on the occurrence of clinical short-and long-term major adverse events (MAE, any stroke or death) or radiological adverse events (new ischemic lesions on postprocedural magnetic resonance diffusion-weighted imaging (MR-DWI), restenosis or stent fracture) in different stent designs used to treat carotid artery stenosis.Random effects models were used to calculate combined overall effect sizes. Meta-regression was performed to identify the effect of specific stents on MAE rates.
Results: From 2,654 unique identified articles, two randomized controlled trials and 66 cohort studies were eligible for analysis (including 46,728 procedures). Short-term clinical MAE rates were similar for patients treated with open cell versus closed cell or hybrid stents. Use of Acculink stent was associated with a higher risk of MAE compared to Wallstent (RR: 1.51, p=0.03), as was true for use of Precise stent versus Xact stent (RR: 1.55, p<0.001). Long-term clinical MAE rates were similar for open versus closed cell stents. Use of open cell stents predisposed to a 25% higher chance (RR: 1.25; p=0.03) of developing postprocedural new ischemic lesions on MR-DWI. No differences were observed in incidence of restenosis, stent fracture, or intraprocedural hemodynamic depression with respect to different stent design. [Type here] Conclusions: Stent design does not affect short-or long-term clinical MAE rates in patients undergoing CAS. Furthermore, the division in open and closed cell stent design might conceal true differences in single stent efficacy. Nevertheless, open cell stenting resulted in a significantly higher number of MR-DWI-detected subclinical postprocedural new ischemic lesions compared with closed cell stenting. An individualized patient data meta-analysis,including future studies with prospective homogenous study design, is required to adequately correct for known risk factors and provide definite conclusions with respect to carotid stent design for specific subgroups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.