The discrete rotational symmetry of nanostructures provides a powerful and simple guiding principle for designing the second-harmonic generation process in nonlinear metamaterials. We demonstrate that, in achiral nanostructures with threefold rotational symmetries, a circularly polarized fundamental beam produces a countercircularly polarized second-harmonic beam. In this case, the polarization state of the second harmonic is determined in a very simple manner. We also demonstrate how rotational symmetries in nonlinear metamaterials manifest themselves in SHG selection rules.
Present macroscopic biomedical imaging methods provide either morphology with high spatial resolution (e.g. CT) or functional/molecular information with lower resolution (e.g. PET). X-ray fluorescence (XRF) from targeted nanoparticles allows molecular or functional imaging but sensitivity has so far been insufficient resulting in low spatial resolution, despite long exposure times and high dose. In the present paper, we show that laboratory XRF tomography with metal-core nanoparticles (NPs) provides a path to functional/molecular biomedical imaging with ~100 µm resolution in living rodents. The high sensitivity and resolution rely on the combination of a high-brightness liquid-metal-jet x-ray source, pencil-beam optics, photon-counting energy-dispersive detection, and spectrally matched NPs. The method is demonstrated on mice for 3D tumor imaging via passive targeting of in-house-fabricated molybdenum NPs. Exposure times, nanoparticle dose, and radiation dose agree well with in vivo imaging.
X-ray fluorescence computed tomography (XFCT) with nanoparticles (NPs) as contrast agents shows potential for molecular biomedical imaging with higher spatial resolution than present methods. To date the technique has been demonstrated on phantoms and mice, however, parameters such as radiation dose, exposure times and sensitivity have not yet allowed for high-spatial-resolutionin vivo longitudinal imaging, i.e., imaging of the same animal at different time points. Here we show in vivo XFCT with spatial resolution in the 200-400 µm range in a proof-of-principle longitudinal study where mice are imaged five times each during an eight-week period following tail-vein injection of NPs. We rely on a 24 keV x-ray pencil-beam-based excitation of in-house-synthesized molybdenum oxide NPs (MoO 2) to provide the high signal-to-background x-ray fluorescence detection necessary for XFCT imaging with low radiation dose and short exposure times. We quantify the uptake and clearance of NPs in vivo through imaging, and monitor animal well-being over the course of the study with support from histology and DNA stability analysis to assess the impact of x-ray exposure and NPs on animal welfare. We conclude that the presented imaging arrangement has potential for in vivo longitudinal studies, putting emphasis on designing biocompatible NPs as the future focus for active-targeting preclinical XFCT.
We demonstrate that nanoparticle x-ray fluorescence computed tomography in mouse-sized objects can be performed with very high spatial resolution at acceptable dose and exposure times with a compact laboratory system. The method relies on the combination of the 24 keV line-emission from a high-brightness liquid-metal-jet x-ray source, pencil-beam-forming x-ray optics, photon-counting energy-dispersive detection, and carefully matched (Mo) nanoparticles. Phantom experiments and simulations show that the arrangement significantly reduces Compton background and allows 100 μm detail imaging at dose and exposure times compatible with small-animal experiments. The method provides a possible path to in vivo molecular x-ray imaging at sub-100 μm resolution in mice.
Nanoparticles (NPs) have been used as contrast agents for several bioimaging modalities. X-ray fluorescence (XRF) tomography can provide sensitive and quantitative 3D detection of NPs. With spectrally matched NPs as contrast agents, we demonstrated earlier in a laboratory system that XRF tomography could achieve high-spatial-resolution tumor imaging in mice. Here, we present the synthesis, characterization, and evaluation of a library of NPs containing Y, Zr, Nb, Rh, and Ru that have spectrally matched K-shell absorption for the laboratory scale X-ray source. The K-shell emissions of these NPs are spectrally well separated from the X-ray probe and the Compton background, making them suitable for the lab-scale XRF tomography system. Their potential as XRF contrast agents is demonstrated successfully in a small-animal equivalent phantom, confirming the simulation results. The diversity in the NP composition provides a flexible platform for a better design and biological optimization of XRF tomography nanoprobes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.