Three experiments studied the effect of stimulus polarity on the Electrically Evoked Compound Action Potential (ECAP) obtained with the masker-probe paradigm on different sites along the cochlea in cochlear implant users. Experiment 1 used a biphasic cathodic-1st (BIC) masker and showed that ECAP N(1) peak latencies were longer for BIC than for biphasic anodic-1st (BIA) probes on all electrodes under test. Both the latency of each probe as well as the latency difference between BIA and BIC probes increased when the phase width (PW) of the masker and probe were increased together. Experiment 2 used maskers with long inter-phase gaps (IPGs), and, by manipulating the polarity of the second phase (closest in time to the biphasic probe), showed that only an anodic phase could mask the probe response. Experiment 3 used maskers and probes with long IPGs and measured ECAPs to the first phase of the probe; ECAPs could be measured when both this phase and the second phase of the masker were anodic, but not when they were cathodic. Our results extend those of a previous study, showing that the auditory nerve in humans is preferentially activated by anodic stimulation, to different sites along the cochlea.
Recent behavioral studies have suggested that the human auditory nerve of cochlear implant (CI) users is mainly excited by the positive (anodic) polarity. Those findings were only obtained using asymmetric pseudomonophasic (PS) pulses where the effect of one phase was measured in the presence of a counteracting phase of opposite polarity, longer duration, and lower amplitude than the former phase. It was assumed that only the short high-amplitude phase was responsible for the excitation. Similarly, it has been shown that electrically evoked compound action potentials could only be obtained in response to the anodic phases of asymmetric pulses. Here, experiment 1 measured electrically evoked auditory brainstem responses to standard symmetric, PS, reversed pseudomonophasic, and reversed pseudomonophasic with inter-phase gap (6 ms) pulses presented for both polarities. Responses were time locked to the short high-amplitude phase of asymmetric pulses and were smaller, but still measurable, when that phase was cathodic than when it was anodic. This provides the first evidence that cathodic stimulation can excite the auditory system of human CI listeners and confirms that this stimulation is nevertheless less effective than for the anodic polarity. A second experiment studied the polarity sensitivity at different intensities by means of a loudness balancing task between pseudomonophasic anodic (PSA) and pseudomonophasic cathodic (PSC) stimuli. Previous studies had demonstrated greater sensitivity to anodic stimulation only for stimuli producing loud percepts. The results showed that PSC stimuli required higher amplitudes than PSA stimuli to reach the same loudness and that this held for current levels ranging from 10 to 100 % of the dynamic range.
The spatial auditory change complex (ACC) is a cortical response elicited by a change in place of stimulation. There is growing evidence that it provides a useful objective measure of electrode discrimination in cochlear implant (CI) users. To date, the spatial ACC has only been measured in relatively experienced CI users with one type of device. Early assessment of electrode discrimination could allow auditory stimulation to be optimized during a potentially sensitive period of auditory rehabilitation. In this study we used a direct stimulation paradigm to measure the spatial ACC in both pre- and post-lingually deafened adults. We show that it is feasible to measure the spatial ACC in different CI devices and as early as 1 week after CI switch-on. The spatial ACC has a strong relationship with performance on a behavioural discrimination task and in some cases provides information over and above behavioural testing. We suggest that it may be useful to measure the spatial ACC to guide auditory rehabilitation and improve hearing performance in CI users.
Humans, and many other species, exploit small differences in the timing of sounds at the two ears (interaural time difference, ITD) to locate their source and to enhance their detection in background noise. Despite their importance in everyday listening tasks, however, the neural representation of ITDs in human listeners remains poorly understood, and few studies have assessed ITD sensitivity to a similar resolution to that reported perceptually. Here, we report an objective measure of ITD sensitivity in electroencephalography (EEG) signals to abrupt modulations in the interaural phase of amplitude-modulated low-frequency tones. Specifically, we measured following responses to amplitude-modulated sinusoidal signals (520-Hz carrier) in which the stimulus phase at each ear was manipulated to produce discrete interaural phase modulations at minima in the modulation cycle—interaural phase modulation following responses (IPM-FRs). The depth of the interaural phase modulation (IPM) was defined by the sign and the magnitude of the interaural phase difference (IPD) transition which was symmetric around zero. Seven IPM depths were assessed over the range of ±22 ° to ±157 °, corresponding to ITDs largely within the range experienced by human listeners under natural listening conditions (120 to 841 μs). The magnitude of the IPM-FR was maximal for IPM depths in the range of ±67.6 ° to ±112.6 ° and correlated well with performance in a behavioural experiment in which listeners were required to discriminate sounds containing IPMs from those with only static IPDs. The IPM-FR provides a sensitive measure of binaural processing in the human brain and has a potential to assess temporal binaural processing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.