CI532 array insertion results in consistent scala tympani location and provides expected audiologic performance. Initial hearing preservation results are not consistent with current electro-acoustic arrays.
Objective: Hearing loss remains a significant morbidity for patients with vestibular schwannomas (VS). A growing number of reports suggest audibility with cochlear implantation following VS resection; however, there is little consensus on preferred timing and cochlear implant (CI) performance. Data Sources: A systematic literature search of the Ovid Medline, Embase, Scopus, and clinicaltrails.gov databases was performed on 9/7/2018. PRISMA reporting guidelines were followed. Study Selection: Included studies reported CI outcomes in an ear that underwent a VS resection. Untreated VSs, radiated VSs, and CIs in the contralateral ear were excluded. Data Extraction: Primary outcomes were daily CI use and attainment of open-set speech. Baseline tumor and patient characteristics were recorded. Subjects were divided into two groups: simultaneous CI placement with VS resection (Group 1) versus delayed CI placement after VS resection (Group 2). Data Synthesis: Twenty-nine articles with 93 patients met inclusion criteria. Most studies were poor quality due to their small, retrospective design. Group 1 had 46 patients, of whom 80.4% used their CI on a daily basis and 50.0% achieved open-set speech. Group 2 had 47 patients, of whom 87.2% used their CI on a daily basis and 59.6% achieved open-set speech. Group 2 had more NF2 patients and larger tumors. CI timing did not significantly impact outcomes. Conclusions: Audibility with CI after VS resection is feasible. Timing of CI placement (simultaneous versus delayed) did not significantly affect performance. Overall, 83.9% used their CI on a daily basis and 54.8% achieved open-set speech.
Objective To explore the immediate and 1-year outcomes of patients who underwent implantation with the slim modiolar electrode (SME). Study Design Consecutive case series with chart review. Setting Tertiary referral academic center. Subject and Methods Between May 2016 and August 2018, a total of 326 cochlear implantations (CIs) were performed. Intraoperative x-rays were performed in all cases to identify tip rollovers. Scalar location was identified for 76 CIs that had postoperative computed tomography reconstructions. Speech outcomes were measured at 3, 6, and 12 months with consonant-nucleus-consonant word and AzBio sentences in quiet and noise (+10-dB signal-to-noise ratio). Preservation of hearing was defined as maintaining a low-frequency pure tone average ≤80 dB at 250 and 500 Hz. Results Among 326 CIs, 23 (7%) had tip rollovers. Postoperative reconstructions revealed 5 of 76 (6.6%) scalar translocations. A subset of 177 cases met criteria for evaluation of speech perception scores. The marginal mean differences between presurgery and 12 months for speech tests were as follows: consonant-nucleus-consonant, 43.7 (95% CI, 39.8-47.6); AzBio in quiet, 49.7 (95% CI, 44.9-54.4); and AzBio in noise, 29.9 (95% CI, 25.2-34.7). Sixty-one patients were identified with preservable hearing (low-frequency pure tone average ≤80 dB), and 12 of 61 (20%) preserved hearing at 1 year. Conclusion CI with SME provides reliable scala tympani insertion in a consistent perimodiolar position. An initially increased tip rollover rate improved with case volume and sheath design improvement. For long-term outcomes, speech performance was comparable to that of other cochlear implants. While hearing preservation for the SME may be better than prior perimodiolar electrodes, consistent outcomes are unlikely.
The size of the electrodes' artefact was smaller on CT compared to MR. Furthermore, the position was not precisely concentric around the electrode. Nevertheless, the mean deviation after measuring the contact position in both CT and MR was less than 1 mm in all three planes. Both techniques are eligible for postoperative localisation of DBS electrodes, with a small imprecision of the non-stereotactic MR compared to the stereotactic CT. This might be compensated by the fact that postoperative MR can rule out asymptomatic postoperative complications e.g. haemorrhages or infarctions, without radiation exposure of the patient.
for the CI532 Study Group IMPORTANCE Hearing loss, especially moderate to severe forms, has the potential to negatively affect an individual's physical, social, emotional, and cognitive well-being. Moreover, having ineffective binaural hearing increases difficulty understanding speech in noise and leads to a greater degree of social isolation and loneliness and a reduced quality of life (QoL).OBJECTIVE To explore the audiometric and holistic effects of cochlear implantation in a group of adults 65 years or older compared with an optimized bilateral hearing aid condition. DESIGN, SETTING, AND PARTICIPANTSThis ad hoc secondary analysis of a prospective, single-subject, repeated-measures nonrandomized clinical trial included 13 cochlear implantation centers across the United States. Participants 65 years or older with postlingual bilateral moderate-to-profound sensorineural hearing loss with aided Consonant-Vowel Nucleus-Consonant (CNC) word scores in quiet of 40% or less in the ear to undergo implantation and 50% or less in the contralateral ear were included in the analysis. Baseline QoL testing was performed after 1 month of optimized bilateral hearing aid use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.