Background
Extracorporeal carbon dioxide removal is an increasingly used respiratory support technique. As is true of all extracorporeal techniques, extracorporeal carbon dioxide removal needs proper anticoagulation. We report a case of a patient at risk of bleeding complications who was treated with extracorporeal carbon dioxide removal and anticoagulated with a regional technique.
Case presentation
A 56-year-old Caucasian man with a history of chronic obstructive pulmonary disease exacerbation required extracorporeal carbon dioxide removal for severe hypercapnia and acidosis despite mechanical ventilation. The extracorporeal circuit was anticoagulated using a regional heparin technique to limit the patient’s risk of bleeding due to a low platelet count. The patient underwent 96 h of effective extracorporeal carbon dioxide removal without any adverse events. He was successfully weaned from extracorporeal carbon dioxide removal. During the treatment, no bleeding complications or unexpected circuit clotting was observed.
Conclusions
The use of regional heparin anticoagulation technique seems to be feasible and safe during extracorporeal carbon dioxide removal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.