BackgroundThe extensive heterogeneity between patients with amyotrophic lateral sclerosis (ALS) complicates the quantification of disease progression. In this study, we determine the value of remote, accelerometer-based monitoring of physical activity in patients with ALS.MethodsThis longitudinal cohort study was conducted in a home-based setting; all study materials were sent by mail. Patients wore the ActiGraph during waking hours for 7 days every 2–3 months and provided information regarding their daily functioning (ALSFRS-R). We defined four accelerometer-based endpoints that either reflect the average daily activity or quantify the patient’s physical capacity.ResultsA total of 42 patients participated; the total valid monitoring period was 9288 h with a 93.0% adherence rate. At baseline, patients were active 27.9% (range 11.6–52.4%) of their time; this declined by 0.64% (95% 0.43–0.86, p < 0.001) per month. Accelerometer-based endpoints were strongly associated with the ALSFRS-R (r 0.78, 95% CI 0.63–0.92, p < 0.001), but showed less variability over time than the ALSFRS-R (coefficient of variation 0.64–0.81 vs. 1.06, respectively). Accelerometer-based endpoints could reduce sample size by 30.3% for 12-month trials and 44.6% for 18-month trials; for trials lasting less than 9 months, the ALSFRS-R resulted in smaller sample sizes.ConclusionAccelerometry is an objective method for quantifying disease progression, which could obtain real-world insights in the patient’s physical functioning and may personalize the delivery of care. In addition, remote monitoring provides patients with the opportunity to participate in clinical trials from home, paving the way to a patient-centric clinical trial model.
Background Poor monitoring of respiratory function may lead to late initiation of non-invasive ventilation (NIV) in patients with motor neuron diseases (MND). Monitoring could be improved by remotely assessing hypoventilation symptoms between clinic visits. We aimed to determine which patient-reported hypoventilation symptoms are best for screening reduced respiratory function in patients with MND, and compared them to the respiratory domain of the amyotrophic lateral sclerosis functional rating scale (ALSFRS-R). Methods This prospective multi-center study included 100 patients with MND, who were able to perform a supine vital capacity test. Reduced respiratory function was defined as a predicted supine vital capacity ≤ 80%. We developed a 14-item hypoventilation symptom questionnaire (HYSQ) based on guidelines, expert opinion and think-aloud interviews with patients. Symptoms of the HYSQ were related to dyspnea, sleep quality, sleepiness/fatigue and pneumonia. The diagnostic performances of these symptoms and the ALSFRS-R respiratory domain were determined from the receiver operating characteristic (ROC) curves, area under the curve (AUC), sensitivity, specificity, predictive values and accuracy. Results Dyspnea-related symptoms (dyspnea while eating/talking, while lying flat and during light activity) were combined into the MND Dyspnea Scale (MND-DS). ROC curves showed that the MND-DS had the best diagnostic performance, with the highest AUC = 0.72, sensitivity = 75% and accuracy = 71%. Sleep-quality symptoms, sleepiness/fatigue-related symptoms and the ALSFRS-R respiratory domain showed weak diagnostic performance. Conclusion The diagnostic performance of the MND-DS was better than the respiratory domain of the ALSFRS-R for screening reduced respiratory function in patients with MND, and is, therefore, the preferred method for (remotely) monitoring respiratory function.
Background We aimed to determine (1) the test–retest reliability of a newly developed portable fixed dynamometer (PFD) as compared to the hand-held dynamometer (HHD) in patients with motor neuron disease (MND) and (2) the PFD’s ability to reduce possible examiner-induced ceiling effects. Methods Test–retest reliability of isometric muscle strength of the quadriceps was measured in patients with MND and non-neurological controls using the HHD and PFD. Reliability was estimated by the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) using linear mixed effects models, and the Bland–Altman method of agreement. Results In total, 45 patients with MND and 43 healthy controls were enrolled in this study. The ICC of the PFD was excellent and similar in both patients and controls (ICC Patients 99.5% vs. ICC Controls 98.6%) with a SEM of 6.2%. A strong examiner-induced ceiling effect in HHD was found when the participant’s strength exceeded that of examiner. Employing the PFD increased the range of muscle strength measurements across individuals nearly twofold from 414 to 783 N. Conclusions Portable fixed dynamometry may significantly reduce examiner-induced ceiling effects, optimize the standardization of muscle strength testing, and maximize reliability. Ultimately, PFD may improve the delivery of care due to its potential for unsupervised, home-based assessments and reduce the burden to the patient of participating in clinical trials for MND or other neuromuscular diseases.
Background Home-monitoring of spirometry has the potential to improve care for patients with a motor neuron disease (MND) by enabling early detection of respiratory dysfunction and reducing travel burden. Our aim was to evaluate the validity and feasibility of home-monitoring vital capacity (VC) in patients with MND. Methods We included 33 patients with amyotrophic lateral sclerosis, progressive muscular atrophy or primary lateral sclerosis who completed a 12-week home-monitoring protocol, consisting of 4-weekly unsupervised home assessments of VC and a functional rating scale. At baseline, during a home visit, patients/caregivers were trained in performing a VC test, and the investigator performed a supervised VC test, which was repeated at final follow-up during a second home visit. Validity of the unsupervised VC tests was evaluated by the differences between supervised and unsupervised VC tests, and through Bland–Altman 95% limits-of-agreement. Feasibility was assessed by means of a survey of user-experiences. Results The 95% limits-of-agreement were [− 14.3; 11.7] %predicted VC, and 88% of unsupervised VC tests fell within 10%predicted of supervised VC. 88% of patients experienced VC testing as easy and not burdensome, however, 15% patients did not think their VC test was performed as well as in the clinic. 94% of patients would like home-monitoring of VC in MND care. Discussion Unsupervised VC testing at home, with prior face-to-face training, is a valid and time-efficient method for the remote monitoring of respiratory function, and well-accepted by patients with MND and their caregivers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.