A continuous femoral nerve block leads to better analgesia, less morphine consumption and less morphine-related side effects after TKA. Early functional recovery is improved, resulting in more patients reaching 90 degrees knee flexion after 6 days. However, after 3 months, no significant functional benefits were found.
This study was designed to identify factors that significantly alter the magnitude and duration of suxamethonium-induced neuromuscular block in patients with an apparently normal genotype for pseudocholinesterase. One hundred and fifty-six adults (ages 18-65 yr) were allocated to 13 subgroups. Patients in each subgroup received suxamethonium 50-2000 micrograms kg-1. The mechanographic response of the adductor pollicis brevis muscle to ulnar nerve stimulation was recorded. The ED50 was found to be 167 micrograms kg-1, ED90 was 316 micrograms kg-1 and ED95 was 392 micrograms kg-1. The duration of action (delta t) was in agreement with earlier published results. The magnitude of block was dose-related and decreased with increasing onset time (ton) and pseudocholinesterase activity (PChA). Neither age nor gender affected the degree of suxamethonium-induced block. Delta t was dose-related, decreased with increasing PChA, and was shorter for women. Age and ton had no effect on delta t.
SummaryWe measured acceleromyography and mechanomyography simultaneously with monitoring of rocuronium-induced neuromuscular block in four patients with myotonic dystrophy type 1. Furthermore, we compared neuromuscular block measures from these patients with those from normal controls from previous studies. In myotonic dystrophy type 1 patients, the dose-response curve obtained with acceleromyography was steeper and right-shifted compared with that obtained using mechanomyography. However, the effective doses to produce 95% neuromuscular block determined with both acceleromyography and mechanomyography were similar to each other and to values found in normal patients. In the three myotonic dystrophy type 1 patients with mild to moderate disease, times to recovery from block were similar to those observed in normal controls. In both patients and normal controls, neuromuscular block recovered faster with acceleromyography. However, in one patient with severe muscle wasting, recovery of neuromuscular block was prolonged. We conclude that mechanomyography and acceleromyography cannot be used interchangeably to monitor neuromuscular block in myotonic dystrophy type 1 patients.
No abstract
Background Telehealth solutions can play an important role in increasing access to eye care. Web-based eye tests can enable individuals to self-assess their visual function remotely without the assistance of an eye care professional. A web-based tool for self-assessing visual acuity (VA) has previously been studied in controlled, supervised conditions. The accuracy of this tool when performed independently by patients in their home environment, using their own devices, has not yet been examined. Objective The objective of this paper was to examine the accuracy of a web-based tool with respect to measuring VA in ophthalmic patients in their home environment, compared with a conventional in-hospital assessment using a Snellen chart (the gold standard). Methods From April through September 2020, consecutive adult patients with uveitis at the University Medical Center Utrecht, the Netherlands, performed the web-based VA test at home (the index test) before their upcoming conventional VA assessment at the hospital (the reference test). The agreement between the 2 tests was assessed by the Bland-Altman analysis. Additional analyses were performed to investigate associations between clinical characteristics and the accuracy of the web-based test. Results A total of 98 eyes in 59 patients were included in the study. The difference in VA between the index and reference tests was not significant, with a mean difference of 0.02 (SD 0.12) logMAR (P=.09) and 95% limits of agreement of –0.21 to 0.26 logMAR. The majority of the differences (77%) fell within the predetermined acceptable deviation limit of 0.15 logMAR. In addition, no patient characteristics or clinical parameters were found to significantly affect the accuracy of the web-based test. Conclusions This web-based test for measuring VA is a valid tool for remotely assessing VA, also when performed independently by patients at home. Implementation of validated web-based tools like this in the health care system may represent a valuable step forward in revolutionizing teleconsultations and can provide individual patients with the opportunity to self-monitor changes in VA. This is particularly relevant when the patient’s access to ophthalmic care is limited. Future developments should focus on optimizing the testing conditions at home to reduce outliers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.