BACKGROUND Bronchoscopy is frequently nondiagnostic in patients with pulmonary lesions suspected to be lung cancer. This often results in additional invasive testing, although many lesions are benign. We sought to validate a bronchial-airway gene-expression classifier that could improve the diagnostic performance of bronchoscopy. METHODS Current or former smokers undergoing bronchoscopy for suspected lung cancer were enrolled at 28 centers in two multicenter prospective studies (AEGIS-1 and AEGIS-2). A gene-expression classifier was measured in epithelial cells collected from the normal-appearing mainstem bronchus to assess the probability of lung cancer. RESULTS A total of 639 patients in AEGIS-1 (298 patients) and AEGIS-2 (341 patients) met the criteria for inclusion. A total of 43% of bronchoscopic examinations were non-diagnostic for lung cancer, and invasive procedures were performed after bronchoscopy in 35% of patients with benign lesions. In AEGIS-1, the classifier had an area under the receiver-operating-characteristic curve (AUC) of 0.78 (95% confidence interval [CI], 0.73 to 0.83), a sensitivity of 88% (95% CI, 83 to 92), and a specificity of 47% (95% CI, 37 to 58). In AEGIS-2, the classifier had an AUC of 0.74 (95% CI, 0.68 to 0.80), a sensitivity of 89% (95% CI, 84 to 92), and a specificity of 47% (95% CI, 36 to 59). The combination of the classifier plus bronchoscopy had a sensitivity of 96% (95% CI, 93 to 98) in AEGIS-1 and 98% (95% CI, 96 to 99) in AEGIS-2, independent of lesion size and location. In 101 patients with an intermediate pretest probability of cancer, the negative predictive value of the classifier was 91% (95% CI, 75 to 98) among patients with a nondiagnostic bronchoscopic examination. CONCLUSIONS The gene-expression classifier improved the diagnostic performance of bronchoscopy for the detection of lung cancer. In intermediate-risk patients with a nondiagnostic bronchoscopic examination, a negative classifier score provides support for a more conservative diagnostic approach. (Funded by Allegro Diagnostics and others; AEGIS-1 and AEGIS-2 ClinicalTrials.gov numbers, NCT01309087 and NCT00746759.)
; for the RENEW Study Research Group IMPORTANCE Preliminary clinical trials have demonstrated that endobronchial coils compress emphysematous lung tissue and may improve lung function, exercise tolerance, and symptoms in patients with emphysema and severe lung hyperinflation. OBJECTIVE To determine the effectiveness and safety of endobronchial coil treatment. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial conducted among 315 patients with emphysema and severe air trapping recruited from 21 North American and 5 European sites from December 2012 through November 2015. INTERVENTIONS Participants were randomly assigned to continue usual care alone (guideline based, including pulmonary rehabilitation and bronchodilators; n = 157) vs usual care plus bilateral coil treatment (n = 158) involving 2 sequential procedures 4 months apart in which 10 to 14 coils were bronchoscopically placed in a single lobe of each lung. MAIN OUTCOMES AND MEASURES The primary effectiveness outcome was difference in absolute change in 6-minute-walk distance between baseline and 12 months (minimal clinically important difference [MCID], 25 m). Secondary end points included the difference between groups in 6-minute walk distance responder rate, absolute change in quality of life using the St George's Respiratory Questionnaire (MCID, 4) and change in forced expiratory volume in the first second (FEV 1 ; MCID, 10%). The primary safety analysis compared the proportion of participants experiencing at least 1 of 7 prespecified major complications. RESULTS Among 315 participants (mean age, 64 years; 52% women), 90% completed the 12-month follow-up. Median change in 6-minute walk distance at 12 months was 10.3 m with coil treatment vs −7.6 m with usual care, with a between-group difference of 14.6 m (Hodges-Lehmann 97.5% CI, 0.4 m to ϱ; 1-sided P = .02). Improvement of at least 25 m occurred in 40.0% of patients in the coil group vs 26.9% with usual care (odds ratio, 1.8 [97.5% CI, 1.1 to ϱ]; unadjusted between-group difference, 11.8% [97.5% CI, 1.0% to ϱ]; 1-sided P = .01). The between-group difference in median change in FEV 1 was 7.0% (97.5% CI, 3.4% to ϱ; 1-sided P < .001), and the between-group St George's Respiratory Questionnaire score improved −8.9 points (97.5% CI, −ϱ to −6.3 points; 1-sided P < .001), each favoring the coil group. Major complications (including pneumonia requiring hospitalization and other potentially life-threatening or fatal events) occurred in 34.8% of coil participants vs 19.1% of usual care (P = .002). Other serious adverse events including pneumonia (20% coil vs 4.5% usual care) and pneumothorax (9.7% vs 0.6%, respectively) occurred more frequently in the coil group. CONCLUSIONS AND RELEVANCE Among patients with emphysema and severe hyperinflation treated for 12 months, the use of endobronchial coils compared with usual care resulted in an improvement in median exercise tolerance that was modest and of uncertain clinical importance, with a higher likelihood of major complications. Further follow-up is need...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.