We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 tonne-years and an unprecedentedly low background rate of 76 AE 2 stat events=ðtonne × year × keVÞ between 1 and 30 keV, the data enable one of the most sensitive searches for solar axions, an enhanced neutrino magnetic moment using solar neutrinos, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4σ significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by g ae < 3.8 × 10 −12 , g ae g eff an < 4.8 × 10 −18 , and g ae g aγ < 7.7 × 10 −22 GeV −1 , and excludes either g ae ¼ 0 or g ae g aγ ¼ g ae g eff an ¼ 0. The neutrino magnetic moment signal is similarly favored over background at 3.2σ, and a confidence interval of μ ν ∈ ð1.4; 2.9Þ × 10 −11 μ B (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by β decays of tritium at 3.2σ significance with a corresponding tritium concentration in xenon of ð6.2 AE 2.0Þ × 10 −25 mol=mol. Such a trace amount can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to 2.0σ and 0.9σ, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ð2.3 AE 0.2Þ keV (68% C.L.) with a 3.0σ global (4.0σ local) significance over background. This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and 210 keV=c 2. We also consider the possibility that 37 Ar may be present in the detector, yielding a 2.82 keV peak from electron capture. Contrary to tritium, the 37 Ar concentration can be tightly constrained and is found to be negligible.
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to 12.3 ± 0.6 (keV t y)-1 and (2.2± 0.5)× 10−3 (keV t y)-1, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of 1.4×10−48 cm2 for a 50 GeV/c2 mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T . In addition, we show that for a 50 GeV/c2 WIMP with cross-sections above 2.6×10−48 cm2 (5.0×10−48 cm2) the median XENONnT discovery significance exceeds 3σ (5σ). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches 2.2×10−43 cm2 (6.0×10−42 cm2).
Xenon dual-phase time projection chambers designed to search for weakly interacting massive particles have so far shown a relative energy resolution which degrades with energy above $$\sim $$∼ 200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $$^{136} \hbox {Xe}$$136Xe at its Q value, $$Q_{\beta \beta }\simeq 2.46\,\hbox {MeV}$$Qββ≃2.46MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at $$1\,\sigma /\mu $$1σ/μ is as low as ($$0.80 \pm 0.02$$0.80±0.02) % in its one-ton fiducial mass, and for single-site interactions at $$Q_{\beta \beta }$$Qββ. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
In 3D topological insulators achieving a genuine bulk-insulating state is an important research topic. Recently, the material system (Bi,Sb) 2 (Te,Se) 3 (BSTS) has been proposed as a topological insulator with high resistivity and a low carrier concentration (Ren et al 2011 Phys. Rev. B 84 165311). Here we present a study to further refine the bulk-insulating properties of BSTS. We have synthesized BSTS single crystals with compositions around x = 0.5 and y = 1.3. Resistance and Hall effect measurements show high resistivity and record low bulk carrier density for the composition Bi 1.46 Sb 0.54 Te 1.7 Se 1.3 . The analysis of the resistance measured for crystals with different thicknesses within a parallel resistor model shows that the surface contribution to the electrical transport amounts to 97% when the sample thickness is reduced to 1 μm. The magnetoconductance of exfoliated BSTS nanoflakes shows 2D weak antilocalization with α ≃ −1 as expected for transport dominated by topological surface states.
We detail the sensitivity of the proposed liquid xenon DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: pp, $$^7$$ 7 Be, $$^{13}$$ 13 N, $$^{15}$$ 15 O and pep. The precision of the $$^{13}$$ 13 N, $$^{15}$$ 15 O and pep components is hindered by the double-beta decay of $$^{136}$$ 136 Xe and, thus, would benefit from a depleted target. A high-statistics observation of pp neutrinos would allow us to infer the values of the electroweak mixing angle, $$\sin ^2\theta _w$$ sin 2 θ w , and the electron-type neutrino survival probability, $$P_{ee}$$ P ee , in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, with 10 live years of data and a 30 tonne fiducial volume. An observation of pp and $$^7$$ 7 Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high- (GS98) and low-metallicity (AGS09) solar models with 2.1–2.5$$\sigma $$ σ significance, independent of external measurements from other experiments or a measurement of $$^8$$ 8 B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $$^{131}$$ 131 Xe.
The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $$^{222}$$ 222 Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a $$^{222}$$ 222 Rn activity concentration of $$10\,\mathrm{\,}\upmu \mathrm{Bq}/\mathrm{kg}$$ 10 μ Bq / kg in $$3.2\,\mathrm{t}$$ 3.2 t of xenon. The knowledge of the distribution of the $$^{222}$$ 222 Rn sources allowed us to selectively eliminate problematic components in the course of the experiment. The predictions from the emanation measurements were compared to data of the $$^{222}$$ 222 Rn activity concentration in XENON1T. The final $$^{222}$$ 222 Rn activity concentration of $$(4.5\pm 0.1)\,\mathrm{\,}\upmu \mathrm{Bq}/\mathrm{kg}$$ ( 4.5 ± 0.1 ) μ Bq / kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.