This determination was made using the electron capture decay of 54Mn. Two methods were employed to measure the K X-ray emission rate: by means of a pressurized 4re proportional counter with the gas at 1.5 MPa, and by means of a medium geometry-defined solid angle counter. The final result was 0~k = 0.2901_+ 0.003. Special care was taken in determining the corrections, some of which do not appear to have been allowed for so far. It is noteworthy that additional corrections, each about + 3 %, had to be applied to the results obtained with each of the two methods. Thus there remains complete agreement between them, but at a higher value of (ok than those appearing in recent publications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.