We studied all patients referred to the orthoptic department with binocular diplopia following cataract surgery between January 1991 and June 1993. Persistence of diplopia for a minimum of 3 months after cataract surgery was required for inclusion in the study. Eighty-one patients (2% of all patients who underwent cataract surgery during this time) satisfied the entry criteria. The patients fell into two groups: non-traumatic and traumatic cataracts. Horizontal deviations were seen in 24 patients. Vertical deviations were seen in 8 patients and a combined horizontal and vertical deviation was seen in 49 patients. Fresnel prisms were used to manage the diplopia in 58 patients. Of these, 48 patients in the non-traumatic group regained binocular single vision with this prism while 10 in the traumatic group benefited. Mechanical and sensory causes are discussed.
Measurement of Stereopsis forms an important part of the clinical assessment of patients with disorders of ocular motility. The introduction of a real depth distance stereoacuity test (FD2) was evaluated in clinical practice and to what extent the introduction affected clinical management. Seventy-three patients under evaluation before and following the introduction of the test were included. Combined thresholds were measured at near using the Frisby and TNO test and at distance using the FD2. Fifty healthy controls were included. Forty-five patients demonstrated Stereopsis using the FD2 and 23 of these had a change in their management based in part on their responses using the FD2. Patients with evidence of Stereopsis using the FD2 were significantly more likely to have change in their management than expected from the whole sample (P = .02). The introduction of a real depth distance stereoacuity test into clinical practice contributed to a change in management when used in conjunction with other tests. The usefulness of the FD2 is limited by its range at 6 m. Use at closer distances necessitates the calculation of binocular threshold from the combined and monocular threshold.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.