Thermocouples are often used for thermoregulation of active thermal systems. When the junctions of these sensors are under a natural convection flow, it is necessary to take into account the viscous stress that can affect the measurement of temperature and therefore the regulation set points. The main objective of this work is to study the viscous shear stress taking place close to the active hot wall in closed air-filled cavities of parallelogrammic shape. The influence of shear stress is examined for different inclination angles of the cavity and large Rayleigh numbers which are usual in thermal applications. The local stress distributions are presented for the steady state for all the geometric configurations considered. The Nusselt number at the hot wall as well as the temperature and stream function distributions in the cavities are also included. The findings obtained from the numerical simulation using the finite volume method are validated by thermal measurements on an experimental cavity. This study confirms the need to properly choose the location of thermocouples in the reference cell used for controlling the active system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.