This cross-sectional study determined the prevalence of Listeria spp. in bulk-tank milk on dairy farms in the region of Galicia in northwest Spain. The aim was to identify management practices associated with the presence of Listeria spp. and possible effects on milk hygienic quality. A total of 98 farms was randomly selected on the basis of an expected prevalence of 6.5% for Listeria monocytogenes from 20,107 dairy farms in the region. Bulk-tank milk samples were obtained from 98 farms, fecal samples from lactating cows from 97 farms, and silage samples from 83 farms. Listeria monocytogenes was detected in 6.1, 9.3, and 6.0% of these samples, respectively. Statistical analyses confirmed the relationship between low silage quality (as indicated by high pH) and presence of Listeria spp. in silage (29.5 vs. 6.2% for pH above or below 4.5, respectively). Only milking system [tie-stall systems (28.6%) vs. parlor milking (10%)] and inadequately controlled milking order [yes (32.0%) vs. no (10.7%)] had statistically significant effects on management practices for increasing the risk of Listeria contamination of bulk-tank milk.
Near-infrared spectroscopy analysis of foodstuffs is a relatively recent
technique. Its principal
advantage is speed of analysis, and it does not require sample
pretreatment either. In this paper
we review its application to powder dairy products, liquid milk,
cheese, butter, and fermented milk
products, mainly from the analysis of the major components point of
view and also for the detection
of adulterations and other determinations as well.
Keywords: Near-infrared spectroscopy; dairy products
NIR transflectance spectroscopy was used to analyze fructose, glucose, and moisture in honey. A total of 161 honey samples were collected during 1992 (46), 1995 (58), and 1996 (57). Samples were analyzed by instrumental, enzymatic (fructose and glucose), and refractometric (moisture) methods. Initially, different calibrations were performed for each of the 3 years of sampling. Good predictions were obtained for all three components with equations of the particular year. But good predictions were not always obtained when the equations calculated one year were applied to samples from another year. To perform a lasting calibration, unique calibration (121 samples) and validation (40 samples) sets were built; honeys of the 3 years were included in both sets. Good statistics (bias, standard error of validation (SEV), and R(2)) were obtained for all three components of the validation set. No statistically significant differences (p = 0.05) were found between instrumental and reference methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.