A supercritical (SC) nitrogen (N 2 ) switch is designed and tested. The dielectric strength and recovery rate of the SC switch are investigated by experiments. In order to theoretically study the discharge and recovery process of the SC N 2 switch under high repetition rate operation, a numerical model is developed. For SC N 2 with initial parameters of p = 80.9 bar and T = 300 K, the simulation results show that within several nanoseconds after the streamer bridges the switch gap, the spark is fully developed and this time depends on the applied electric field between electrodes. During the whole discharge process, the maximum temperature in the channel is about 20 000 K. About 10 µs after the spark excitation of 200 ns duration, the temperature on the axis decays to T axis 1500 K, mainly contributed by the gas expansion and heat transfer mechanisms. After 100 µs, the dielectric strength of the gap recovers to above half of the cold breakdown voltage due to the temperature decay in the channel. Both experimental and numerical investigations indicate that supercritical fluid is a good insulating medium that has a proved high breakdown voltage and fast recovery speed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.