SummaryCytoreductive surgery with hyperthermic intraperitoneal chemotherapy (HIPEC) is a long and complex procedure with significant blood and fluid loss during debulking and important pathophysiological alterations during the HIPEC phase. We performed a retrospective analysis of 78 consecutive patients undergoing cytoreductive surgery with HIPEC at a university hospital. Our data demonstrate large intra-operative fluid turnover, with 51% of patients requiring a blood transfusion. During HIPEC, airway pressure and central venous pressure increased with a lower oxygenation ratio as a result of increased intra-abdominal pressure with the closed abdomen technique. As a consequence of the raised body temperature, heart rate, end tidal carbon dioxide and arterial lactate levels increased with a slight metabolic acidosis. Peri-operative analysis of routine clotting parameters revealed disturbances of the coagulation status. For pain management, 72% of patients received supplementary thoracic epidural analgesia with consequential perioperative opioid sparing and a reduced duration of postoperative ventilation.
We have analysed the clinical agreement between two methods of continuous cardiac output measurement pulse contour analysis (PCCO) and a continuous thermodilution technique (CCO), were both compared with the intermittent bolus thermodilution technique (BCO). Measurements were performed in 26 cardiac surgical patients (groups 1 and 2, 13 patients each, with an ejection fraction > 45% and < 45%, respectively) at 12 selected times. During operation, mean differences (bias) between PCCO-BCO and CCO-BCO did not differ in either group. However, phenylephrine-induced increases in systemic vascular resistance (SVR) by approximately 60% resulted in significant differences. Significantly higher absolute bias values of PCCO-BCO compared with CCO-BCO were also found early after operation in the ICU. Thus PCCO and CCO provided comparable measurements during coronary bypass surgery. After marked changes in SVR, further calibration of the PCCO device is necessary.
Abstract-Our study aimed to characterize the mechanisms underlying the attenuated cardiovascular responsiveness toward the renin-angiotensin system during sepsis. For this purpose, we determined the effects of experimental Gram-negative and Gram-positive sepsis in rats. We found that sepsis led to a ubiquitous upregulation of NO synthase isoform II expression and to pronounced hypotension. Despite increased plasma renin activity and plasma angiotensin (Ang) II levels, plasma aldosterone concentrations were normal, and the blood pressure response to exogenous Ang II was markedly diminished in septic rats. Mimicking the fall of blood pressure during sepsis by short-term infusion of the NO donor sodium nitroprusside in normal rats did not alter their blood pressure response to exogenous Ang II. Therefore, we considered the possibility of an altered expression of Ang II receptors during sepsis. It turned out that Ang II type 1 receptor expression was markedly downregulated in all organs of septic rats. Further in vitro studies with rat renal mesangial cells showed that NO and a combination of proinflammatory cytokines (interleukin-1, tumor necrosis factor-␣, and interferon-␥) downregulated Ang II type 1 receptor expression in a synergistic fashion. In summary, our data suggest that sepsis causes a systemic downregulation of Ang II type 1 receptors that is likely mediated by proinflammatory cytokines and NO. We suggest that this downregulation of Ang II type 1 receptors is the main reason for the attenuated responsiveness of blood pressure and of aldosterone formation to Ang II and, therefore, contributes to the characteristic septic shock. (Hypertension. 2001;38:177-182.)
SummaryWe report the findings of a study on exposure of operating room staff to sevoflurane, halothane and nitrous oxide during induction and maintenance of anaesthesia in children. Concentrations of anaesthetic agents in the operating theatre were measured directly by highly sensitive, photoacoustic infrared spectrometer during 20 anaesthetics. Samples were taken from the breathing zones of the anaesthetist and the circulating nurse. The operating theatre was of modern design with an air conditioning system providing 20 changes of air each hour. The threshold values of 100 ppm N 2 O, 50 ppm isoflurane and 10 ppm halothane recommended by the United Kingdom Committee for Occupational Safety and Health (COSH) were exceeded in several cases for a short time during mask induction. After tracheal intubation, trace concentrations of sevoflurane, halothane and N 2 O were mostly under the recommended levels and comparable to levels measured during adult anaesthesia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.