We have developed a sample holder design that allows for electrical conductivity measurements on a disk-shaped sample. The sample holder design is based on and compatible with popular measurement systems that are currently restricted to bar-shaped samples. The geometrical correction factors which account for the adjusted measurement configuration were calculated using finite element modeling for a broad range of sample and measurement geometries. We also show that the modeling results can be approximated by a simple analytical fit function with excellent accuracy. The proposed sample holder design is compatible with a concurrent measurement of the Seebeck coefficient. The chosen sample geometry is furthermore compatible with a thermal conductivity measurement using a laser flash apparatus. A complete thermoelectric characterization without cutting the sample is thus possible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.