Purpose. We propose an approach for treating ocular melanoma using a new type of brachytherapy treatment device. This device couples Yb-169, a middle-energy high dose rate (HDR) brachytherapy source, with a gold shielded ring applicator to better conform radiation exposures to the tumor. In this study, we computationally test the dosimetric output of our proposed shielded ring applicator design using MCNP6 and validate it against an I-125 COMS plaque. Methods. The proposed Yb-169 ring applicator consists of an assembly of discrete sources delivered into an applicator with a conical collimated opening; this opening is tangent to the outside of the source tube. Using MCNP6, we simulated the dosimetric output of a ring of Yb-169 pellets placed within the collimator at various conical diameters and angles to demonstrate the dosimetric distribution for various prescription dose depths and target sizes using static intensity modulation. Results. Using various angles of collimation, the prescription dose was delivered to target apex depths of 3.5–8.0 mm into the eye covering target sizes ranging from 10 to 15 mm in diameter. This proposed device reduced the maximum absorbed dose to critical structures relative to I-125 by 5.2% to the posterior lens, 9.3% to the iris, 13.8% to the optic nerve, and 1.3% to the sclera. Conclusions. This proposed eye plaque design provides a more conformal dose distribution to the ocular tumor while minimizes dose to healthy ocular structures. In addition, the use of a middle-energy HDR brachytherapy source allows the use of a remote afterloader to expose the tumor after the plaque is sutured in place. This system is inherently safer and eliminates dose to the surgeon’s hands.
Purpose: A prototype 169 Yb source was developed in combination with a dynamic rotating platinum shield system (AIM-Brachy) to deliver intensity modulated brachytherapy (IMBT). The purpose of this study was to evaluate the dosimetric characteristics of the bare/shielded 169 Yb source using Monte Carlo (MC) simulations and perform an independent dose verification using a dosimetry platform based on a multipoint plastic scintillator detector (mPSD). Methods: The TG-43U1 dosimetric parameters were calculated for the source model using Rapid-BrachyMCTPS. Real-time dose rate measurements were performed in a water tank for both the bare/ shielded source using a custom remote afterloader. For each dwell position, the dose rate was independently measured by the three scintillators (BCF-10, BCF-12, and BCF-60). For the bare source, dose rate was measured at distances up to 3 cm away from the source over a range of 7 cm along the catheter. For the shielded source, measurements were performed with the mPSD placed at 1 cm from the source at four different azimuthal angles (0 , 90 , 180 , and 270). Results: The dosimetric parameters were tabulated for the source model. For the bare source, differences between measured and calculated along-away dose rates were generally below 5-10%. Along the transverse axis, deviations were, on average (range), 3.3% (0.6-6.2%) for BCF-10, 1.7% (0.9-2.9%) for BCF-12, and 2.2% (0.3-4.4%) for BCF-60. The maximum dose rate reduction due to shielding at a radial distance of 1 cm was 88.8 AE 1.2%, compared to 83.5 AE 0.5% as calculated by MC. Conclusions: The dose distribution for the bare/shielded 169 Yb source was independently verified using mPSD with good agreement in regions close to the source. The 169 Yb source coupled with the partial-shielding system is an effective technique to deliver IMBT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.