An automated inhibitor affinity extraction method for the activity-based enrichment of matrix metallo-proteases (MMPs) is presented. Samples containing purified MMP-12 were first extracted at different flow rates in a syringe pump setup, using cartridges packed with an MMP inhibitor affinity sorbent based on an immobilized hydroxamic acid containing peptide (PLG-NHOH) with mumol/L MMP affinity. Faster extractions, a reduced number of manual manipulations, and higher extraction yields (98.9%-99.3%) were obtained over the whole flow rate range compared to batch extractions. Application of the method to synovial fluid from a rheumatoid arthritis patient followed by gelatin-zymography revealed a strong enrichment of distinct MMPs from this biological sample that were not clearly visible in the original sample. The use of an auto-sampler and a solid-phase extraction (SPE) workstation allowed full automation of the extraction procedure with the potential for on-line coupling to further sample preparation and analytical steps. MMP-12 extractions were optimized showing that ligand density is an important factor with a clear extraction yield optimum around 5 to 7.5 mmol/L. Conditioning of the stationary phase for 1 week prior to use resulted in a further slight increase in extraction yield. Under optimal conditions, an extraction yield of 99.5% was reached with a cartridge contact time of only 13 s for MMP-12. The efficacy of the extraction method for activity-based MMP profiling was further improved by the use of a broad-spectrum MMP inhibitor with nmol/L affinity (TAPI-2). This resulted in an increased extraction yield for all tested MMPs. For MMP-1, -7, -8, -10, -12, and -13 extraction yields of at least 98.8% were obtained, while for MMP-9 (full length and catalytic domain) an extraction yield of at least 96.1% was reached.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.