Purpose. To estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo (MC) codes of low-energy photon cross-sections (<200 keV). Methods. MC simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Three dosimetry-relevant quantities are considered: mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra. The absorbed dose and the photon-fluence spectra are scored in a spherical water phantom of 15 cm radius. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a good estimator for the corresponding Type B uncertainties. Results. A conservative Type B uncertainty for the absorbed dose (k = 2) of 1.2%–1.7% (<50 keV), 0.6%–1.2% (50–100 keV), and 0.3% (100–200 keV) is estimated. The photon-fluence spectrum does not present clinically relevant differences that merit considering additional Type B uncertainties except for energies below 25 keV, where a Type B uncertainty of 0.5% is obtained. Below 30 keV, mass energy-absorption coefficients show Type B uncertainties (k = 2) of about 1.5% (water and air), and 2% (graphite), diminishing in all materials for larger energies and reaching values about 1% (40–50 keV) and 0.5% (50–75 keV). With respect to their ratios, the only significant Type B uncertainties are observed in the case of the water-to-graphite ratio for energies below 30 keV, being about 0.7% (k = 2). Conclusions. In contrast with the intermediate (about 500 keV) or high (about 1 MeV) energy domains, Type B uncertainties due to the different cross-sections implementation cannot be considered subdominant with respect to Type A uncertainties or even to other sources of Type B uncertainties (tally volume averaging, manufacturing tolerances, etc). Therefore, the values reported here should be accommodated within the uncertainty budget in low-energy photon dosimetry studies.
Objective: To investigate an approach for quantitative characterization of the spatial distribution of dosimetric data by introducing Haralick texture feature analysis in this context. Approach: Monte Carlo simulations are used to generate data for 2 scenarios: (1) cell-scale microdosimetry: specific energies (energy imparted per unit mass) in cell-scale targets irradiated by photon spectra (125I, 192Ir, 6 MV); (2) patient-scale dosimetry: doses in voxels for idealized patient models undergoing 125I permanent implant prostate brachytherapy, considering ``TG186'' (realistic tissues including 0 to 5% intraprostatic calcifications; interseed attenuation) and ``TG43'' (water model, no interseed attenuation) conditions. Five prominent Haralick features (homogeneity, contrast, correlation, local homogeneity, entropy) are considered and trends are interpreted using fundamental radiation physics. Main results: In the cell-scale scenario, the Haralick measures quantify differences in 3D specific energy distributions due to source spectra. For example, contrast and entropy are highest for 125I reflecting the large variations in specific energy in adjacent voxels (photoelectric interactions; relatively short range of electrons), while 6 MV has the highest homogeneity with smaller variations in specific energy between voxels (Compton scattering dominates; longer range of electrons). For the patient-scale scenario, the Haralick measures quantify differences due to TG186/TG43 simulation conditions and the presence of calcifications. For example, as calcifications increase from 0 to 5%, contrast increases while correlation decreases, reflecting the large differences in doses in adjacent voxels (higher doses in voxels with calcification due to photoelectric interactions). Significance: Haralick texture analysis provides a quantitative method for the characterization of 3D dosimetric distributions across cellular to tumour length scales, with promising future applications including analyses of multiscale tissue models, patient-specific data, and comparison of treatment approaches.
Purpose The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro‐spectroscopy scanning of radiochromic film (RCF). The goal is to generate dose calibration curves over an extended dose range from 0 to 50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating the uncertainties in dose estimation associated with the calibration curves. Methods Samples of RCF (EBT3) were irradiated at a broad dose range of 0.03–50 Gy using an Elekta Synergy clinical linear accelerator. Raman spectra were acquired with a custom‐built Raman micro‐spectroscopy setup involving a 500 mW, multimode 785 nm laser focused to a lateral spot diameter of 30 µm on the RCF. The depth of focus of 34 µm enabled the concurrent collection of Raman spectra from the RCF active layer and the polyester laminate. The preprocessed Raman spectra were normalized to the intensity of the 1614 cm−1 Raman peak from the polyester laminate that was unaltered by radiation. The mean intensities and the corresponding standard deviation of the active layer Raman peaks at 696, 1445, and 2060 cm−1 were determined for the 150 × 100 µm2 scan area per dose value. This was used to generate three calibration curves that enabled the conversion of the measured Raman intensity to dose values. The experimental, fitting, and total dose uncertainty was determined across the entire dose range for the dosimetry system of Raman micro‐spectroscopy and RCF. Results In contrast to previous work that investigated the Raman response of RCFs using different methods, high resolution in the dose response of the RCF, even down to 0.03 Gy, was obtained in this study. The dynamic range of the calibration curves based on all three Raman peaks in the RCF extended up to 50 Gy with no saturation. At a spatial resolution of 30 × 30 µm2, the total uncertainty in estimating dose in the 0.5–50 Gy dose range was [6–9]% for all three Raman calibration curves. This consisted of the experimental uncertainty of [5–8]%, and the fitting uncertainty of [2.5–4.5]%. The main contribution to the experimental uncertainty was determined to be from the scan area inhomogeneity which can be readily reduced in future experiments. The fitting uncertainty could be reduced by performing Raman measurements on RCF samples at further intermediate dose values in the high and low dose range. Conclusions The high spatial resolution experimental dosimetry technique based on Raman micro‐spectroscopy and RCF presented here, could become potentially useful for applications in microdosimetry to produce meaningful dose estimates in cellular targets, as well as for applications based on small field dosimetry that involve high dose gradients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.