HPMC capsules are made by a dipping process and a surface lubricant for the mould pins is an essential processing aid for removing dried capsules shells. For the purpose of this study, the level was determined by quantifying methyloleate (MO) a component found in the lubricant but not in the hypromellose capsules. Here we investigated the influence of the lubricant, low (10.81 μg/capsule=60 mg/kg MO), medium (15.97 μg/capsule=90 mg/kg MO) and high (23.23 μg/capsule=127 mg/kg MO) content on powder (binary mixture of salbutamol: lactose, 1:50 w/w) aerosolization properties was investigated. Results indicated significantly lower emitted dose from capsules with 60 mg/kg MO. Furthermore, the 90 and 127 mg/kg MO level of lubricant capsules produced almost double the Fine Particle Dose & Fine Particle Fraction compared with the low level of lubricant. The data indicates that lubricant level within capsules has an influence on deposition profiles and amount of drug remaining in capsule and inhaler device after actuation. It is suggested lubricant levels greater than 60 mg/kg MO per capsule are required to minimise powder retention within capsules and maximise deposition profiles. AFM (atomic force microscopy) data suggest that internal surface roughness may be related with this phenomena.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.