Exhaled breath temperature (EBT) is a biomarker of inflammation and vascularity of the airways already shown to predict incident COPD. This cross-sectional study was aimed to assess the potential of EBT in identifying “healthy” smokers susceptible to cigarette smoke toxicity of the airways and to the risk of developing COPD by analysing the dynamics of EBT after smoking a cigarette and its associations with their demographics (age, smoking burden) and lung function. The study included 55 current smokers of both sexes, 29–62 years of age, with median smoking exposure of 15 (10–71.8) pack-years. EBT was measured at baseline and 5, 15, 30, 45, and 60 min after smoking a single cigarette. Lung function was measured with spirometry followed by a bronchodilator test. To compare changes in EBT between repeated measurements we used the analysis of variance and the area under the curve (EBTAUC) as a dependent variable. Multivariate regression analysis was used to look for associations with patient characteristics and lung function in particular. The average (±SD) baseline EBT was 33.42±1.50 °C. The highest significant increase to 33.84 (1.25) °C was recorded 5 min after the cigarette was smoked (p=0.003), and it took one hour for it to return to the baseline. EBTAUC showed significant repeatability (ICC=0.85, p<0.001) and was significantly associated with age, body mass index, number of cigarettes smoked a day, baseline EBT, and baseline FEF75 (R2=0.39, p<0.001 for the model). Our results suggest that EBT after smoking a single cigarette could be used as early risk predictor of changes associated with chronic cigarette smoke exposure.
Exhaled breath temperature (EBT) is a known biomarker of inflammation and airways blood flow. As opposed to previous studies, we were able to measure temperature of separate fractions of exhaled breath (fEBT) (those from the peripheral and central airways). The aim was to validate the fEBT measurement method to determine the reference values and the influence of endogenous and exogenous factors on fEBT in healthy subjects. This cross-sectional study included 55 healthy adults in whom fEBT was repeatedly measured, two days in a row, using a FractAir® device. Also, basal metabolic rate, level of physical activity, distance from the main road, outdoor and ambient temperature, air pressure and humidity, haematology and inflammation markers, lung function, cumulative EBT and body temperature at characteristic points on the body were measured. The results showed that fEBT from central airways was lower compared to fEBT from the periphery and that fEBTs were not related to body temperature (p > 0.05 for all). We also showed repeatability of fEBT measurements for two consecutive days. All EBT fractions correlated significantly with ambient temperature (<0.01). No associations of fEBT with other personal and external factors were found using multivariate analysis. At room temperature of 22 °C, the physiological temperature values of the first fraction were 23.481 ± 3.150 °C, the second fraction 26.114 ± 4.024 °C and the third fraction 28.216 ± 3.321 °C. The proposed reference values represent the first part of validation of fEBT as the method for the use in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.