In this paper, novel methods for detecting steady-state visual evoked potentials using multiple electroencephalogram (EEG) signals are presented. The methods are tailored for brain-computer interfacing, where fast and accurate detection is of vital importance for achieving high information transfer rates. High detection accuracy using short time segments is obtained by finding combinations of electrode signals that cancel strong interference signals in the EEG data. Data from a test group consisting of 10 subjects are used to evaluate the new methods and to compare them to standard techniques. Using 1-s signal segments, six different visual stimulation frequencies could be discriminated with an average classification accuracy of 84%. An additional advantage of the presented methodology is that it is fully online, i.e., no calibration data for noise estimation, feature extraction, or electrode selection is needed.
Brain-computer interface (BCI) systems enable communication without movement. It is unclear why some BCI approaches or parameters are less effective with some users. This study elucidates BCI demographics by exploring correlations among BCI performance, personal preferences, and different subject factors such as age or gender. Results showed that most people, despite having no prior BCI experience, could use the Bremen SSVEP BCI system in a very noisy field setting. Performance tended to be better in both young and female subjects. Most subjects stated that they did not consider the flickering stimuli annoying and would use or recommend this BCI system. These and other demographic analyses may help identify the best BCI for each user.
A Brain–Computer Interface (BCI) provides a novel non-muscular communication method via brain signals. A BCI-speller can be considered as one of the first published BCI applications and has opened the gate for many advances in the field. Although many BCI-spellers have been developed during the last few decades, to our knowledge, no reviews have described the different spellers proposed and studied in this vital field. The presented speller systems are categorized according to major BCI paradigms: P300, steady-state visual evoked potential (SSVEP), and motor imagery (MI). Different BCI paradigms require specific electroencephalogram (EEG) signal features and lead to the development of appropriate Graphical User Interfaces (GUIs). The purpose of this review is to consolidate the most successful BCI-spellers published since 2010, while mentioning some other older systems which were built explicitly for spelling purposes. We aim to assist researchers and concerned individuals in the field by illustrating the highlights of different spellers and presenting them in one review. It is almost impossible to carry out an objective comparison between different spellers, as each has its variables, parameters, and conditions. However, the gathered information and the provided taxonomy about different BCI-spellers can be helpful, as it could identify suitable systems for first-hand users, as well as opportunities of development and learning from previous studies for BCI researchers.
In recent years, there has been increased interest in using steady-state visual evoked potentials (SSVEP) in brain-computer interface (BCI) systems; the SSVEP approach currently provides the fastest and most reliable communication paradigm for the implementation of a non-invasive BCI. This paper presents recent developments in the signal processing of the SSVEP-based Bremen BCI system, which allowed one of the subjects in an online experiment to reach a peak information transfer rate (ITR) of 124 bit min(-1). It is worth mentioning that this ITR value is higher than all values previously published in the literature for any kind of BCI paradigm.
Brain-computer interface (BCI) systems use brain activity as an input signal and enable communication without movement. This study is a successor of our previous study (BCI demographics I) and examines correlations among BCI performance, personal preferences, and different subject factors such as age or gender for two sets of steady-state visual evoked potential (SSVEP) stimuli: one in the medium frequency range (13, 14, 15 and 16 Hz) and another in the high-frequency range (34, 36, 38, 40 Hz). High-frequency SSVEPs (above 30 Hz) diminish user fatigue and risk of photosensitive epileptic seizures. Results showed that most people, despite having no prior BCI experience, could use the SSVEP-based Bremen-BCI system in a very noisy field setting at a fair. Results showed that demographic parameters as well as handedness, tiredness, alcohol and caffeine consumption, etc., have no significant effect on the performance of SSVEP-based BCI. Most subjects did not consider the flickering stimuli annoying, only five out of total 86 participants indicated change in fatigue during the experiment. 84 subjects performed with a mean information transfer rate of 17.24 ±6.99 bit/min and an accuracy of 92.26 ±7.82% with the medium frequency set, whereas only 56 subjects performed with a mean information transfer rate of 12.10 ±7.31 bit/min and accuracy of 89.16 ±9.29% with the high-frequency set. These and other demographic analyses may help identify the best BCI for each user.
Current brain-computer interfaces (BCIs) that make use of EEG acquisition techniques require unpleasant electrode gel causing skin abrasion during the standard preparation procedure. Electrodes that require tap water instead of electrolytic electrode gel would make both daily setup and clean up much faster, easier and comfortable. This paper presents the results from ten subjects that controlled an SSVEP-based BCI speller system using two EEG sensor modalities: water-based and gel-based surface electrodes. Subjects performed in copy spelling mode using conventional gel-based electrodes and water-based electrodes with a mean information transfer rate (ITR) of 29.68 ± 14.088 bit min(-1) and of 26.56 ± 9.224 bit min(-1), respectively. A paired t-test failed to reveal significant differences in the information transfer rates and accuracies of using gel- or water-based electrodes for EEG acquisition. This promising result confirms the operational readiness of water-based electrodes for BCI applications.
A brain-computer interface (BCI) provides the possibility to translate brain neural activity patterns into control commands without user's movement. The brain activity is most commonly measured non-invasively via standard electroencephalography (EEG), i.e., with electrodes placed on the surface of the scalp. In this article, we evaluate a BCI system based on steady-state visual evoked potentials (SSVEPs) in real world conditions. Although the performance of this type of BCI has already been proved by several research groups with healthy users in laboratory settings assisted by scientific researchers, there are still many difficulties in changing from demonstration systems to practical BCIs. The Bremen-BCI was evaluated in this case study with 37 naive subjects (without any SSVEP-BCI experience), including 8 handicapped users, at the international rehabilitation fair RehaCare2008. In spite of unsuitable environment conditions on the fair, the spelling tasks were successfully completed by 32 participants with a mean accuracy of over 92% and an average information transfer rate (ITR) of 22.6[bits/min]. No significant dependency of the physical disability of participants on the ITR could be observed.
Brain-Computer Interfaces (BCIs) transfer human brain activities into computer commands and enable a communication channel without requiring movement. Among other BCI approaches, steady-state visual evoked potential (SSVEP)-based BCIs have the potential to become accurate, assistive technologies for persons with severe disabilities. Those systems require customization of different kinds of parameters (e.g., stimulation frequencies). Calibration usually requires selecting predefined parameters by experienced/trained personnel, though in real-life scenarios an interface allowing people with no experience in programming to set up the BCI would be desirable. Another occurring problem regarding BCI performance is BCI illiteracy (also called BCI deficiency). Many articles reported that BCI control could not be achieved by a non-negligible number of users. In order to bypass those problems we developed a SSVEP-BCI wizard, a system that automatically determines user-dependent key-parameters to customize SSVEP-based BCI systems. This wizard was tested and evaluated with 61 healthy subjects. All subjects were asked to spell the phrase “RHINE WAAL UNIVERSITY” with a spelling application after key parameters were determined by the wizard. Results show that all subjects were able to control the spelling application. A mean (SD) accuracy of 97.14 (3.73)% was reached (all subjects reached an accuracy above 85% and 25 subjects even reached 100% accuracy).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.