SummaryApplication of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot® cervical collar and with the patient’s head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope® and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack–Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients’ tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43–61 s). The modified Cormack–Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi‐rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.
Despite prior contrary reports, a CFNB did not result in femoral nerve injuries or worsened functional outcomes after ACL reconstruction. The improvement of analgesia with a CFNB was only marginal and not clinically relevant beyond 24 hours. Registration: NCT01321138 ( ClinicalTrials.gov identifier).
SummaryFibreoptic intubation remains a key technique for the management of difficult intubation. We randomly compared the second generation single-use Ambu
Animal data have demonstrated increased block duration after local anaesthetic injections in diabetic rat models. Whether the same is true in humans is currently undefined. We, therefore, undertook this prospective cohort study to test the hypothesis that type-2 diabetic patients suffering from diabetic peripheral neuropathy would have increased block duration after ultrasound-guided popliteal sciatic nerve block when compared with patients without neuropathy. Thirty-three type-2 diabetic patients with neuropathy and 23 non-diabetic control patients, scheduled for fore-foot surgery, were included prospectively. All patients received an ultrasound-guided popliteal sciatic nerve block with a 30 ml 1:1 mixture of lidocaine 1% and bupivacaine 0.5%. The primary outcome was time to first opioid request after block procedure. Secondary outcomes included the time to onset of sensory blockade, and pain score at rest on postoperative day 1 (numeric rating scale 0-10). These outcomes were analysed using an accelerated failure time regression model. Patients in the diabetic peripheral neuropathy group had significantly prolonged median (IQR [range]) time to first opioid request (diabetic peripheral neuropathy group 1440 (IQR 1140-1440 [180-1440]) min vs. control group 710 (IQR 420-1200 [150-1440] min, p = 0.0004). Diabetic peripheral neuropathy patients had a time ratio of 1.57 (95%CI 1.10-2.23, p < 0.01), experienced a 59% shorter time to onset of sensory blockade (median time ratio 0.41 (95%CI 0.28-0.59), p < 0.0001) and had lower median (IQR [range]) pain scores at rest on postoperative day 1 (diabetic peripheral neuropathy group 0 (IQR 0-1 [0-5]) vs. control group 3 (IQR 0-5 [0-9]), p = 0.001). In conclusion, after an ultrasound-guided popliteal sciatic nerve block, patients with diabetic peripheral neuropathy demonstrated reduced time to onset of sensory blockade, with increased time to first opioid request when compared with patients without neuropathy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.