Aims: To determine the fit factor and compliance with American Industrial Hygiene Association (AIHA) and Occupational Safety and Health Administration (OSHA) requirements of surgical masks and filtering respirators in male versus female nurses.
Design:A case-control gender study performed from 2016 to 2019. Methods: A gender and age matched-paired sample of 74 nurses was recruited and divided into men (n = 37) and women (n = 37). FFP3 filtering respirators and surgical masks fit factors were compared between male and female nurses by Mann-Whitney U tests. These measurements were tested to pass or fail according to the OSHA (≥100) and AIHA (≥50) criteria by Fisher exact tests for a 95% confidence interval.Results: Global fit factor mean (standard deviation) was 2.86 (2.73) and 3.55 (6.34) for male and female nurses wearing surgical masks (p = .180), respectively, and nobody passed neither OSHA nor AIHA criteria (p = 1.00). Nevertheless, global fit factor were 30.82 (28.42) and 49.65 (43.04) for male and female nurses wearing FFP3 respirators, respectively, being significantly lower and worse in male nurses (p = .037). According to OSHA criteria, only 2.70% and 13.51% of male and females nurses, respectively, passed with non-significant difference (p = .199), meanwhile 21.62% and 48.64% of male and female nurses, respectively, passed AIHA criteria showing significant differences (p = .027) wearing FFP3 respirators.Conclusions: All male and female nurses wearing surgical masks failed to pass OSHA and AIHA criteria. Global fit factor of the proposed FFP3 filtering respirators was decreased and worse in male than female nurses.
In this study, an aluminum insole in a motorcycling boot was shown to decrease maximum pressure on the foot. Comfort was significantly higher than that from ethylene vinyl acetate or commercial boot inserts. This increased comfort and decreased pressure should result in increased safety and control for motorcyclists.
Background: The lateral ankle ligament complex is the most frequently injured ligament secondary to strong ankle inversion movement during lateral ankle sprains (LAS). Among these injuries, anterior talofibular ligament (ATFL) injury is the most frequent condition (present in 66-85% of such injuries). The purpose of this research was to use magnetic resonance imaging (MRI) to determine the association between ankle tendon, ligament, and joint conditions and ATFL injuries.Methods: A case-control MRI study was carried out to compare the presence of ankle muscle, tendon, ligament, and joint conditions in patients with injured ATFLs (case group; n=25) and non-injured ATFLs (control group; n=25).Results: Achilles tendinopathy was present in 1/25 (4%) patients with injured ATFLs and 7/25 (28%) noninjured ATFL subjects (P=0.048). Injured calcaneofibular ligaments (CFLs) were present in 19/25 (76%) patients with injured ATFLs and 1/25 (4%) non-injured ATFL subjects (P<0.001). Finally, injured tibiotalar joints were present in 16/25 (64%) patients with injured ATFLs and 5/25 (20%) non-injured ATFL subjects (P=0.002). Other musculoskeletal structure injuries occurred at similar rates between patients with injured ATFLs and those with non-injured ATLFs (P≥0.05).Conclusions: Patients with ATFL injuries showed a greater presence of CFL and tibiotalar joint injuries than subjects with non-injured ATFLs.
BackgroundHypertension is considered as a main risk factor for chronic kidney disease development and progression. Thus, the control and evaluation of this disease with new software and devices are especially important in patients who suffer from chronic kidney disease.ObjectiveThis study aimed to validate the QardioArm mobile device, which is used for blood pressure (BP) self-measurement in patients who suffer from chronic kidney disease, by following the European Society of Hypertension International Protocol 2 (ESH-IP2) guidelines.MethodsA validation study was carried out by following the ESH-IP2 guidelines. A sample of 33 patients with chronic kidney disease self-measured their BP by using the QardioArm and Omron M3 Intellisense devices. Heart rate (HR), diastolic BP, and systolic BP were measured.ResultsThe QardioArm fulfilled the ESH-IP2 validation criteria in patients who suffered from chronic kidney disease.ConclusionsThus, this study is considered as the first validation using a wireless upper arm oscillometric device connected to an app to measure BP and HR meeting the ESH-IP2 requirements in patients who suffer from chronic kidney disease. New validation studies following the ESH-IP2 guidelines should be carried out using different BP devices in patients with specific diseases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.