Contrast-enhanced ultrasound (CEUS) is a safe, relatively inexpensive, and widely available imaging technique using dedicated imaging ultrasound sequences and FDA-approved contrast microbubbles that allow detection and characterization of malignant focal liver lesions with high diagnostic accuracy. CEUS provides dynamic real-time imaging with high spatial and temporal capability, allowing for unique contributions to the already established protocols for diagnosing focal liver lesions using CT and MR imaging. In patients with lesions indeterminate on CT and MRI, CEUS is a helpful problem-solving complementary tool that improves patient management. Furthermore, CEUS assists guidance of liver biopsies and local treatment. Variations of CEUS such as DCE-US and ultrasound molecular imaging are emerging for quantitative monitoring of treatment effects and possible earlier detection of cancer. In this review, basic principles of CEUS techniques and ultrasound contrast agents along with a description of the enhancement patterns of malignant liver lesions are summarized. Also, a discussion of the role of CEUS for treatment guidance and monitoring, intraoperative CEUS, and an outlook on emerging applications is provided.
Purpose: To perform a clinical assessment of quantitative three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) feasibility and repeatability in patients with liver metastasis, and to evaluate the extent of quantitative perfusion parameter sampling errors in 2D compared to 3D DCE-US imaging.Materials and Methods: Twenty consecutive 3D DCE-US scans of liver metastases were performed in 11 patients (45% women; mean age, 54.5 years; range, 48-60 years; 55% men; mean age, 57.6 years; range, 47-68 years). Pairs of repeated disruption-replenishment and bolus DCE-US images were acquired to determine repeatability of parameters. Disruption-replenishment was carried out by infusing 0.9 mL of microbubbles (Definity; Latheus Medical Imaging) diluted in 35.1 mL of saline over 8 min. Bolus consisted of intravenous injection of 0.2 mL microbubbles. Volumes-of-interest (VOI) and regions-or-interest (ROI) were segmented by two different readers in images to extract 3D and 2D perfusion parameters, respectively. Disruption-replenishment parameters were: relative blood volume (rBV), relative blood flow (rBF). Bolus parameters included: time-to-peak (TP), peak enhancement (PE), area-under-the-curve (AUC), and mean-transit-time (MTT).Results: Clinical feasibility and repeatability of 3D DCE-US using both the destruction-replenishment and bolus technique was demonstrated. The repeatability of 3D measurements between pairs of repeated acquisitions was assessed with the concordance correlation coefficient (CCC), and found to be excellent for all parameters (CCC > 0.80), except for the TP (0.74) and MTT (0.30) parameters. The CCC between readers was found to be excellent (CCC > 0.80) for all parameters except for TP (0.71) and MTT (0.52). There was a large Coefficient of Variation (COV) in intra-tumor measurements for 2D parameters (0.18-0.52). Same-tumor measurements made in 3D were significantly different (P = 0.001) than measurements made in 2D; a percent difference of up to 86% was observed between measurements made in 2D compared to 3D in the same tumor.Conclusions: 3D DCE-US imaging of liver metastases with a matrix array transducer is feasible and repeatable in the clinic. Results support 3D instead of 2D DCE US imaging to minimize sampling errors due to tumor heterogeneity.
Purpose: Quantitative ultrasound approaches can capture tissue morphologic properties to augment clinical diagnostics. This study aims to clinically assess whether quantitative ultrasound spectroscopy (QUS) parameters measured in hepatocellular carcinoma (HCC) tissues can be differentiated from those measured in at-risk or healthy liver parenchyma.Experimental Design: This prospective Health Insurance Portability and Accountability Act (HIPAA)-compliant study was approved by the Institutional Review Board. Fifteen patients with HCC, 15 non-HCC patients with chronic liver disease, and 15 healthy volunteers were included (31.1% women; 68.9% men). Ultrasound radiofrequency data were acquired in each patient in both liver lobes at two focal depths (3/9 cm). Region of interests (ROIs) were drawn on HCC and liver parenchyma. The average normalized power spectrum for each ROI was extracted, and a linear regression was fit within the À6 dB bandwidth, from which the midband fit (MBF), spectral intercept (SI), and spectral slope (SS) were extracted. Differences in QUS parameters between the ROIs were tested by a mixed-effects regression.Results: There was a significant intraindividual difference in MBF, SS, and SI between HCC and adjacent liver parenchyma (P < 0.001), and a significant interindividual difference between HCC and at-risk and healthy non-HCC parenchyma (P < 0.001). In patients with HCC, cirrhosis (n ¼ 13) did not significantly change any of the three parameters (P > 0.8) in differentiating HCC from non-HCC parenchyma. MBF (P ¼ 0.12), SI (P ¼ 0.33), and SS (P ¼ 0.57) were not significantly different in non-HCC tissue among the groups.Conclusions: The QUS parameters are significantly different in HCC versus non-HCC liver parenchyma, independent of underlying cirrhosis. This could be leveraged for improved HCC detection with ultrasound in the future.
The purpose of the present investigation was to determine whether the beneficial effects of polyunsaturated fatty acids (PUFA) may influence ischemia-reperfusion-induced alterations of myocardial alpha- and beta-adrenoceptor (alpha-AR, beta-AR) responsiveness. This study was carried out using monolayer cultures of neonatal rat ventricular myocytes in a substrate-free, hypoxia-reoxygenation model of ischemia. The cardiomyocytes (CM) were incubated during 4 days in media enriched either with n-6 PUFA (arachidonic acid, AA) or with n-3 PUFA (eicosapentaenoic acid, EPA, and docosahexaenoic acid, DHA). The n-6/n-3 ratio in n-3 CM was close to 1.2, compared to 20.1 in n-6 CM. The contractile parameters of n-6 CM and n-3 CM were similar in basal conditions as well as during hypoxia and reoxygenation. In basal conditions, the phospholipid (PL) enrichment with long chain n-3 PUFA resulted in an increased chronotropic response to isoproterenol (ISO) and to phenylephrine (PHE). After posthypoxic reoxygenation, the chronotropic response to beta-AR activation in n-6 CM was significantly enhanced as compared with the control response in normoxia. In opposition, the ISO-induced rise in frequency in n-3 CM in control normoxia and after reoxygenation was similar. In these n-3 CM, the changes in contractile parameters, which accompanied the chronotropic response, were also similar in reoxygenation and in normoxic periods, although the rise in shortening velocity was slightly increased after reoxygenation. In response to PHE addition, only the chronotropic effect of n-6 CM appeared significantly enhanced after hypoxic treatment. These results suggested that increasing n-3 PUFA in PL reduced the increase in alpha- and beta-AR functional responses observed after hypoxia-reoxygenation. This effect may partly account for the assumed cardiac protective effect of n-3 PUFA, through the attenuation of the functional response to catecholamines in the ischemic myocardium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.