This study evaluated the protocols of sonic and vacuum irrigation regarding the capacity of debris removal from root canal systems. Canal preparations were carried out on 30 mandibular first molars using the ProTaper Universal System. Teeth were divided into two experimental groups (n=15): Group 1: sonic irrigation and Group 2: vacuum irrigation protocol. Subsequently, the mesial roots were sectioned and observed by stereomicroscopy and scanning electron microscopy. Three independent examiners evaluated images of the apical thirds according to the following scores: 1= small presence of debris, 2= moderate presence of debris, and 3= dense presence of debris. Data were analyzed with ANOVA and Kruskal-Wallis tests (α=0.05). Comparison among the groups revealed that at the apical third, the root halves of Group 1 had significantly less surface debris (p=0.002) than those of Group 2. However, at 2 mm from the working length, Group 2's specimens showed less remaining debris in approximately 75% of the analyzed root canals. At the whole apical third, the sonic irrigation protocol removed significantly more debris than the vacuum protocol. However, in the region at 2 mm from the working length, the second irrigation method demonstrated a better performance.
Torsional overload is a fracture representative parameter for instruments in single-file techniques. Objective The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use.Material and Methods Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05.Results WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis.Conclusion After clinical use, no statistically significant reduction in the torsional resistance was observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.