Introduction Portal and mesenteric venous thrombosis is a rare but potentially serious complication after laparoscopic sleeve gastrectomy. There are no consistent studies that prove the safety and effectiveness of oral anticoagulant thromboprophylaxis with rivaroxaban after laparoscopic sleeve gastrectomy. The objective was to evaluate the effect of rivaroxaban on the frequency of portal and mesenteric venous thrombosis and its safety profile after laparoscopic sleeve gastrectomy. Materials and methods This retrospective analysis of prospectively collected data includes all laparoscopic sleeve gastrectomies performed by a single surgeon at Pontificia Universidad Católica de Chile Hospital between January 2009 and June 2019. All patients received low molecular weight heparin thromboprophylaxis during the whole hospital stay. Between July 2012 and June 2019, patients received additional post-discharge thromboprophylaxis with rivaroxaban. Patient demographics, impaired renal, post-surgical portal and mesenteric venous thrombosis, and bleeding episodes were registered. Results A total of 516 patients were identified; 95 patients were excluded. Results for 421 patients were analysed: 198 received only intrahospital thromboprophylaxis (group 1) and 223 received additional post-discharge thromboprophylaxis with rivaroxaban (group 2). There was no statistically significant difference between the two groups concerning age, sex and body mass index. In group 1, four cases of portal and mesenteric venous thrombosis were registered and no cases were reported in group 2 (p < 0.05). All cases occurred before 30 days after surgery. No bleeding episodes and no adverse reactions were detected in group 2. Conclusions Thromboprophylaxis during the whole hospital stay (two to three days), followed by rivaroxaban 10mg once daily for 10 days after discharge (completing in total 13–14 days of prophylaxis), could reduce cases of post-surgical portal and mesenteric venous thrombosis without an increase in bleeding complications.
Objective: To compare the measurement of the Cobb angle in printed radiographs and digitalized radiographs displayed with the "PixViewer" tool. Methods: Pre-operative radiographs of 23 patients were performed in printed films and using the software "PixViewer". The same evaluator, a spine surgeon, chose the proximal and distal end vertebrae at the limit of the main curve in printed radiographs without identifying patients, and measured the Cobb angle based on these parameters. The same parameters and measurements were performed in digitalized radiographs. The measurements were compared, as well as the choice of end vertebrae. Results: The average change in the Cobb angle between the methods was 1.48±1.73°. The intraclass correlation coefficient (ICC) was 0.99, demonstrating excellent reproducibility. Conclusion: The Cobb method can be used to evaluate scoliosis through the "PixViewer" tool with the same reliability of the classic method on printed radiographs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.