Microarrays with biomolecules (e.g., DNA and proteins), cells, and tissues immobilized on solid substrates are important tools for biological research, including genomics, proteomics, and cell analysis. In this paper, the current state of microarray fabrication is reviewed. According to spot formation techniques, methods are categorized as "contact printing" and "non-contact printing." Contact printing is a widely used technology, comprising methods such as contact pin printing and microstamping. These methods have many advantages, including reproducibility of printed spots and facile maintenance, as well as drawbacks, including low-throughput fabrication of arrays. Non-contact printing techniques are newer and more varied, comprising photochemistrybased methods, laser writing, electrospray deposition, and inkjet technologies. These technologies emerged from other applications and have the potential to increase microarray fabrication throughput; however, there are several challenges in applying them to microarray fabrication, including interference from satellite drops and biomolecule denaturization.
We introduce a new method for implementing cell-based assays. The method is based on digital microfluidics (DMF) which is used to actuate nanolitre droplets of reagents and cells on a planar array of electrodes. We demonstrate that this method is advantageous for cell-based assays because of automated manipulation of multiple reagents in addition to reduced reagent use and analysis time. No adverse effects of actuation by DMF were observed in assays for cell viability, proliferation, and biochemistry. A cytotoxicity assay using Jurkat T-cells was performed using the new method, which had approximately 20 times higher sensitivity than a conventional well plate assay. These results suggest that DMF has great potential as a simple yet versatile analytical tool for implementing cell-based assays on the microscale.
We introduce the first lab-on-a-chip platform for complete mammalian cell culture. The new method is powered by digital microfluidics (DMF), a technique in which nanolitre-sized droplets are manipulated on an open surface of an array of electrodes. This is the first application of DMF to adherent cell culture and analysis, and more importantly, represents the first microfluidic platform capable of implementing all of the steps required for mammalian cell culture-cell seeding, growth, detachment, and re-seeding on a fresh surface. Three key innovations were required to implement complete cell culture on a microfluidic device: (1) a technique for growing cells on patterned islands (or "adhesion pads") positioned on an array of DMF actuation electrodes; (2) a method for rapidly and efficiently exchanging media and other reagents on cells grown on adhesion pads; and (3) a system capable of detachment and collection of cells from an (old) origin site and delivery to a (new) destination site for subculture. The new technique was applied to cells from several different lines which were seeded and repeatedly subcultured for weeks at a time in 150 nL droplets. Cells handled in this manner exhibited growth characteristics and morphology comparable to those cultured in standard tissue culture vessels. To illustrate an application for this system, a microfluidic method was developed to implement transient transfection-we propose that the combination of this technique with multigenerational culture allows for "on-demand" generation of transiently transfected cells. Broadly, we anticipate that the automated cell microculture technique presented here will be useful in myriad applications that would benefit from automated mammalian cell culture.
A new dielectrophoretic particle separation method is demonstrated and examined in the following experimental study. Current electrodeless dielectrophoretic (DEP) separation techniques utilize insulating solid obstacles in a DC or low-frequency AC field, while this novel method employs an oil droplet acting as an insulating hurdle between two electrodes. When particles move in a non-uniform DC field locally formed by the droplet, they are exposed to a negative DEP force linearly dependent on their volume, which allows the particle separation by size. Since the size of the droplet can be dynamically changed, the electric field gradient, and hence DEP force, becomes easily controllable and adjustable to various separation parameters. By adjusting the droplet size, particles of three different diameter sizes, 1 microm, 5.7 microm and 15.7 microm, were successfully separated in a PDMS microfluidic chip, under applied field strength in the range from 80 V cm-1 to 240 V cm-1. A very effective separation was realized at the low field strength, since the electric field gradient was proved to be a more significant parameter for particle discrimination than the applied voltage. By utilizing low strength fields and adaptable field gradient, this method can also be applied to the separation of biological samples that are generally very sensitive to high electric potential.
Digital microfluidics (DMF), a fluid-handling technique in which picolitre-microlitre droplets are manipulated electrostatically on an array of electrodes, has recently become popular for applications in chemistry and biology. DMF devices are reconfigurable, have no moving parts, and are compatible with conventional high-throughput screening infrastructure (e.g., multiwell plate readers). For these and other reasons, digital microfluidics has been touted as being a potentially useful new tool for applications in multiplexed screening. Here, we introduce the first digital microfluidic platform used to implement parallel-scale cell-based assays. A fluorogenic apoptosis assay for caspase-3 activity was chosen as a model system because of the popularity of apoptosis as a target for anti-cancer drug discovery research. Dose-response profiles of caspase-3 activity as a function of staurosporine concentration were generated using both the digital microfluidic method and conventional techniques (i.e., pipetting, aspiration, and 96-well plates.) As expected, the digital microfluidic method had a 33-fold reduction in reagent consumption relative to the conventional technique. Although both types of methods used the same detector (a benchtop multiwell plate reader), the data generated by the digital microfluidic method had lower detection limits and greater dynamic range because apoptotic cells were much less likely to de-laminate when exposed to droplet manipulation by DMF relative to pipetting/aspiration in multiwell plates. We propose that the techniques described here represent an important milestone in the development of digital microfluidics as a useful tool for parallel cell-based screening and other applications.
Digital microfluidics (DMF) is a fluid handling technique that enables manipulation of discrete droplets on an array of electrodes. There is considerable enthusiasm for this method because of the potential for array-based screening applications. A limitation for DMF is nonspecific adsorption of reagents to device surfaces. If a given device is used to actuate multiple reagents, this phenomenon can cause undesirable cross-contamination. A second limitation for DMF (and all other microfluidic systems) is the "world-to-chip" interface; it is notoriously difficult to deliver reagents and samples to such systems without compromising the oft-hyped advantages of rapid analyses and reduced reagent consumption. We introduce a new strategy for digital microfluidics, in which a removable plastic "skin" is used to (a) eliminate cross-contamination and (b) bridge the world-to-chip interface. We demonstrated the utility of this format by implementing on-chip protein digestion on immobilized enzyme depots. This new method has the potential to transform DMF from being a curiosity for aficionados into a technology that is useful for biochemical applications at large.
The purpose of this study is to investigate electro-osmotic flow in a free surface-guided microchannel. Although multiphase microfluidics has attracted interests over the past few years, electro-osmotic flow involving free surfaces has yet to be studied in great detail. Several proposed theoretical models describing this type of electro-osmotic flow need to be verified by experiments. In this work, a surface-guided microchannel was fabricated using an innovative fabrication process. Because the liquid stream was confined by surface properties, solid sidewalls did not exist in this microchannel. Instead, the sidewalls were water-air or water-oil interfaces. Using this microchannel, two systems were investigated: water-air system and water-oil system. The experimental results were compared against three proposed models in order to gain more understandings on this type of electro-osmotic flow. Experimental results show that the liquid velocity near the liquid-fluid interface resembles a pluglike profile for both water-air and water-oil systems. Computer simulation results show that with the consideration of the electrical double layer and the surface charges, the electric forces inside the electrical double layer are counteracted by the surface forces at the liquid-fluid interface, also resulting in a pluglike velocity profile in the microchannel. Therefore, the model that considers both the electrical double layer and the surface charges at the liquid-fluid interface best describe the physical phenomenon observed in experiments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.