Summary Background The number of atrial premature depolarisations (APDs) is a known risk factor for atrial fibrillation (AF) recurrence in humans. Objectives To evaluate if the number of APDs over a 24‐h period 5 days post cardioversion predicts AF recurrence within 1 year in horses, taking the multifactorial nature of AF into account. Study design Retrospective case series. Methods Eighty horses met these inclusion criteria: first AF episode, no AF recurrence within 5 days post cardioversion, cardioversion by transvenous electrical cardioversion (TVEC), 24‐h ECG recording and echocardiographic examination 5 days post cardioversion, no antiarrhythmic treatment during the ECG recording and follow‐up of minimum 1 year. To compare the APD burden between the recurrence and non‐recurrence group a Mann–Whitney U test was used. A multivariable survival model was built to identify additional risk factors for AF recurrence. Results The patient population mainly consisted of Warmbloods (93%). Twenty‐six horses (33%) experienced AF recurrence within 1 year. The number of APDs (median [range]) was significantly higher (P = 0.01) in the recurrence group (15 [1–152]) compared with the non‐recurrence group (7 [0–304]). In the multivariable survival model, APDs ≥25/24 h (hazard ratio [HR] 2.9, 95% confidence interval [CI] 1.2–6.8, P = 0.02), mitral regurgitation (HR 8.6, 95% CI 2.6–28.9, P<0.001), left atrial active fractional area change ≤9.6% (HR 2.6, 95% CI 1.0–6.5, P = 0.04) and lower body weight (HR 0.99, 95% CI 0.98–0.99, P = 0.001) were significantly associated with AF recurrence. Main limitations This study did not evaluate early AF recurrence within 5 days. The results cannot necessarily be extrapolated to other treatment methods, as only horses converted by TVEC were included. Conclusions The APD burden 5 days post cardioversion could be a useful predictive value for AF recurrence within 1 year in horses. However, other factors such as mitral regurgitation and atrial contractile function must also be taken into account.
Background Transvenous electrical cardioversion (TVEC) is 1 of the main treatment options for atrial fibrillation (AF) in horses. Large‐scale studies on factors affecting success and prognosis have primarily been performed in Standardbred populations. Hypothesis/Objectives To determine factors affecting cardioversion success, cardioversion difficulty and recurrence in a predominant Warmblood study sample. Animals TVEC records of 199 horses. Methods Retrospective study of TVEC procedures of horses admitted for AF without severe echocardiographic abnormalities. Horse and procedural factors for success and cumulative amount of energy (≤ 600 J vs > 600 J) were determined using multivariable logistic regression. A survival analysis was performed to determine risk factors for recurrence. Results Two hundred and thirty‐one TVEC procedures were included, with a 94.4% success rate and 31.9% recurrence rate (51/160). Mitral regurgitation (OR 0.151, 95% CI 0.032‐0.715, P = .02) and AF cycle length (OR 1.05, 95% CI 1.01‐1.09, P = .02) were independent determinants for success. Catheter type (OR 0.154, 95% CI 0.074‐0.322, P < .001), previous AF episode (OR 3.10, 95% CI 1.20‐8.01, P = .02), tricuspid regurgitation (OR 2.54, 95% CI 1.25‐5.13, P = .01), and body weight (OR 1.009, 95% CI 1.003‐1.015, P = .004) were significantly correlated with cumulative amount of energy delivered. Significant risk factors for recurrence after a first AF episode were sex (stallion; HR 3.05, 95% CI 1.34‐6.95, P = .008), mitral regurgitation (HR 1.91, 95% CI 1.08‐3.38, P = .03), and AF duration (HR 1.001, 95% CI 1.0001‐1.0026, P = .04). Conclusions and Clinical Importance Both horse and procedural factors should be considered when assessing treatment options and prognosis in horses with AF.
Background: Echocardiographic reference intervals for Friesian horses are poorly described. Objectives: To obtain reference intervals for echocardiographic measurements in Friesians and compare these with Warmbloods. Animals: One hundred healthy adult Friesians and 100 healthy adult Warmblood horses. Methods: Cross-sectional study. Two-dimensional and M-mode echocardiographic images were obtained. Echocardiographic measurements, including size, area, and volumetric measurements of left atrium, left and right ventricle, aorta, and pulmonary artery, were performed. Measurements were compared between the 2 breeds using an independent samples t test with Bonferroni correction for multiple comparisons. Results: Reference ranges for standard echocardiographic measurements in Friesians were obtained. Several left ventricular measurements were significantly smaller in Friesians compared to Warmbloods, such as the left ventricular end-diastolic volume using the 4-chamber modified Simpsons' method (99.85% confidence interval for the difference [CI] = −245 to −63). Also the right ventricular end-diastolic and peaksystolic internal diameter were smaller in Friesians (99.85% CI = −1.33 to −0.6 and 99.85% CI = −1.54 to −0.76, respectively). Fractional shortening (99.85% CI = 0.61-6) and ejection fraction (99.85% CI = 0.21-4.6) were significantly larger. No structural effects of systemic hypertension, such as concentric hypertrophy, were detected. Conclusions and Clinical Importance: Our study provides reference intervals for echocardiographic measurements in Friesians useful in a clinical setting. In general, the left ventricular dimensions in Friesians were significantly smaller compared to Warmbloods, emphasizing the need for breed-specific reference intervals. Abbreviations: 4C, 4-chamber view; 4C-AL (in subscript), based on the 4-chamber area-length method; 4C-MOD (in subscript), based on the 4-chamber modified Simpson'
Rate‐adaptive single chamber pacemakers with accelerometer, closed loop stimulation (CLS), and remote monitoring functionality (Eluna 8 SR‐T, Biotronik, SE & Co, Germany) were implanted in 3 miniature donkeys with third‐degree atrioventricular block and syncope. After recovery, different pacemaker programming modes were tested at rest, during stress without physical exercise and during physical exercise. Pacing rates were compared to actual atrial rates and showed that CLS functionality allowed physiological heart rate adaptation. A transmitter installed in the stable provided wireless connection of the pacemaker to the internet. Home monitoring was activated which performed daily wireless transmission of pacemaker functional measurements to an online server allowing diagnosis of pathological arrhythmias and pacemaker malfunction from a distance. Closed loop stimulation and remote monitoring functionality resulted in nearly physiological rate adaptation and allowed remote “from‐the‐stable” patient follow‐up.
Background: Atrial tachycardia (AT) can be treated by medical or electrical cardioversion but the recurrence rate is high. Three-dimensional electro-anatomical mapping, recently described in horses, might be used to map AT to identify a focal source or reentry mechanism and to guide treatment by radiofrequency ablation.Objectives: To describe the feasibility of 3D electro-anatomical mapping and radiofrequency catheter ablation to characterize and treat sustained AT in horses.Animals: Nine horses with sustained AT.Methods: Records from horses with sustained AT referred for radiofrequency ablation at Ghent University were reviewed. Results:The AT was drug resistant in 4 out of 9 horses. In 8 out of 9 horses, AT originated from a localized macro-reentrant circuit (n = 5) or a focal source (n = 3) located at the transition between the right atrium and the caudal vena cava. In these 8 horses, local radiofrequency catheter ablation resulted in the termination of AT. At followup, 6 out of 8 horses remained free of recurrence.Conclusions and Clinical Importance: Differentiation between focal and macroreentrant AT in horses is possible using 3D electro-anatomical mapping. In this study, the source of right atrial AT in horses was safely treated by radiofrequency catheter ablation.
We describe the diagnosis and treatment of an atrioventricular accessory pathway (AP) in a horse using 3‐dimensional electro‐anatomical mapping (3D EAM) and radiofrequency catheter ablation (RFCA). During routine evaluation of the horse, intermittent ventricular pre‐excitation was identified on the ECG, characterized by a short PQ interval and abnormal QRS morphology. A right cranial location of the AP was suspected from the 12‐lead ECG and vectorcardiography. After precise localization of the AP using 3D EAM, ablation was performed and AP conduction was eliminated. Immediately after recovery from anesthesia an occasional pre‐excited complex still was observed, but a 24‐hour ECG and an ECG during exercise 1 and 6 weeks after the procedure showed complete disappearance of pre‐excitation. This case shows the feasibility of 3D EAM and RFCA to identify and treat an AP in horses.
Background: Ventricular septal defects (VSDs) are the most common congenital cardiac defect in horses.Objectives: To identify prevalence, age, breed, and sex distribution of VSD and to describe associated clinical and ultrasonographic findings.Animals: Hospital-based population of 21 136 horses presented to the equine internal medicine department.Methods: Medical records over a 12-year period were reviewed for VSD confirmed by ultrasonography. Age, breed, sex, sport discipline, murmur, clinical signs, outcome, VSD type, VSD size, shunt velocity, cardiac dimensions, concomitant cardiac anomalies, and valvular regurgitations were recorded.Results: From 1894 horses that underwent echocardiography, 54 had a VSD: 42 as an isolated lesion and 12 as part of complex congenital heart disease (CHD). Median age was 5 years (range, 0-26) and 1 year (range, 0-8), respectively. Warmbloods and males were overrepresented. In the isolated VSD group, only 15% had associated clinical signs and most horses had a perimembranous VSD (pmVSD; 36/42). Horses with a pmVSD and clinical signs showed a significantly lower maximal shunt velocity (3.77 vs 5.20 m/s; P < .001), higher VSD/Aortic root (Ao) diameter (0.52 vs 0.38; P = .05), higher left atrium/Ao diameter (1.94 vs 1.22; P < .001), and higher pulmonary artery/Ao diameter (1.15 vs 0.88; P = .005) compared to horses without clinical signs. All horses with complex CHD had clinical signs and abnormal cardiac dimensions. Conclusion and ClinicalImportance: Most isolated VSD were diagnosed only at a later age and were not associated with clinical signs. Horses with complex CHD were more likely to have or develop clinical signs at younger age.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.