OBJECTIVE To investigate the pharmacokinetic and pharmacodynamic properties and safety of a novel formulation of insulin aspart (AT247) versus two currently marketed insulin aspart formulations (NovoRapid [IAsp] and Fiasp [faster IAsp]). RESEARCH DESIGN AND METHODS This single-center, randomized, double-blind, three-period, crossover study was conducted in 19 men with type 1 diabetes, receiving single dosing of trial products (0.3 units/kg) in a random order on three visits. Pharmacokinetics and pharmacodynamics were assessed during a euglycemic clamp lasting up to 8 h. RESULTS Onset of insulin appearance was earlier for AT247 compared with IAsp (−12 min [95% CI −14; −8], P = 0.0004) and faster IAsp (−2 min [−5; −2], P = 0.0003). Onset of action was accelerated compared with IAsp (−23 min [−37; −15], P = 0.0004) and faster IAsp (−9 min [−11; −3], P = 0.0006). Within the first 60 min, a higher exposure was observed for AT247 compared with IAsp by the area under the curve (AUC) glucose infusion rate (GIR) from 0 to 60 min (AUCAsp0–60min: treatment ratio vs. IAsp 2.3 [1.9; 2.9] vs. faster IAsp 1.5 [1.3; 1.8]), which was underpinned by a greater early glucose-lowering effect (AUCGIR,0–60min: treatment ratio vs. IAsp 2.8 [2.0; 5.5] vs. faster IAsp 1.7 [1.3; 2.3]). Furthermore, an earlier offset of exposure was observed for AT247 compared with IAsp (−32 min [−58; −15], P = 0.0015) and faster IAsp (−27 min [−85; −15], P = 0.0017), while duration of the glucose-lowering effect, measured by time to late half-maximum effect, did not differ significantly. CONCLUSIONS AT247 exhibited an earlier insulin appearance, exposure, and offset, with corresponding enhanced early glucose-lowering effect compared with IAsp and faster IAsp. It therefore represents a promising candidate in the pursuit for second-generation prandial insulin analogs to improve postprandial glycemic control.
BACKGROUND Lactulose is approved for the symptomatic treatment of constipation, a gastrointestinal (GI) complication common in individuals with diabetes. Lactulose products contain carbohydrate impurities ( e.g., lactose, fructose, galactose), which occur during the lactulose manufacturing process. These impurities may affect the blood glucose levels of individuals with type 2 diabetes mellitus (T2DM) using lactulose for the treatment of mild constipation. A previous study in healthy subjects revealed no increase in blood glucose levels after oral lactulose intake. However, it is still unclear whether the intake of lactulose increases blood glucose levels in individuals with diabetes. AIM To evaluate the blood glucose profile after oral lactulose intake in mildly constipated, non-insulin-dependent subjects with T2DM in an outpatient setting. METHODS This prospective, double-blind, randomized, controlled, single-center trial was conducted at the Clinical Research Center at the Medical University of Graz, Austria, in 24 adult Caucasian mildly constipated, non-insulin-dependent subjects with T2DM. Eligible subjects were randomized and assigned to one of six treatment sequences, each consisting of four treatments stratified by sex using an incomplete block design. Subjects received a single dose of 20 g or 30 g lactulose (crystal and liquid formulation), water as negative control or 30 g glucose as positive control. Capillary blood glucose concentrations were measured over a period of 180 min post dose. The primary endpoint was the baseline-corrected area under the curve of blood glucose concentrations over the complete assessment period [AUC baseline_c (0-180 min) ]. Quantitative comparisons were performed for both lactulose doses and formulations vs water for the equal lactulose dose vs glucose, as well as for liquid lactulose vs crystal lactulose. Safety parameters included GI tolerability, which was assessed at 180 min and 24 h post dose, and adverse events occurring up to 24 h post dose. RESULTS In 24 randomized and analyzed subjects blood glucose concentration-time curves after intake of 20 g and 30 g lactulose were almost identical to those after water intake for both lactulose formulations despite the different amounts of carbohydrate impurities (≤ 3.0% for crystals and approx. 30% for liquid). The primary endpoint [AUC baseline_c (0-180 min) ] was not significantly different between lactulose and water regardless of lactulose dose and formulation. Also with regard to all secondary endpoints lactulose formulations showed comparable results to water with one exception concerning maximum glucose level. A minor increase in maximum blood glucose was observed after the 30 g dose, liquid lactulose, in comparison to water with a mean treatment difference...
OBJECTIVE <p>To investigate the pharmacokinetic and pharmacodynamic properties, and safety of a novel formulation of insulin aspart (AT247) versus currently marketed insulin aspart formulations (IAsp and faster IAsp).</p> <p> </p> <p>RESEARCH DESIGN AND METHODS</p> <p>This single-center, randomized, double-blind, three-period, crossover study was conducted in 19 men with type 1 diabetes, receiving single dosing of trial products (0.3 U/kg) in a random order on three visits. Pharmacokinetics and pharmacodynamics were assessed during a euglycemic clamp lasting up to 8 hours. </p> <p> </p> <p>RESULTS</p> <p>Onset of insulin appearance was earlier for AT247 compared with IAsp (−12 minutes [95% CI −14;−8] p=0.0004) and faster IAsp (−2 minutes [−5;−2] p=0.0003). Onset of action was accelerated compared with IAsp (−23 minutes [−37;−15] p=0.0004) and faster IAsp (−9 minutes [−11;−3] p=0.0006). Within the first 60 minutes, a higher exposure was observed for AT247 compared with IAsp (AUC<sub>Asp,0-60min</sub>: treatment ratio vs IAsp 2.3 [1.9;2.9]; vs faster IAsp 1.5 [1.3;1.8]), which was underpinned by a greater early glucose-lowering effect (AUC<sub>GIR,0-60min</sub>: treatment ratio vs IAsp 2.8 [2.0;5.5]; vs faster IAsp 1.7 [1.3;2.3]). Furthermore, an earlier offset of exposure was observed for AT247 compared with IAsp (−32 minutes [−58;−15] p=0.0015) and faster IAsp (−27 minutes [−85;−15] p=0.0017), while duration of glucose-lowering effect, measured by t<sub>Late50%GIRmax</sub>, did not differ significantly.</p> <p> </p> <p>CONCLUSIONS</p> <p>AT247 exhibited an earlier insulin appearance, exposure and offset, with corresponding enhanced early glucose-lowering effect compared with IAsp and faster IAsp. It therefore represents a promising candidate in the pursuit for second generation prandial insulin analogs to improve postprandial glycemic control.</p>
PurposeAccumulating evidence points towards a close relationship between cardiovascular, endocrine and metabolic diseases. The BioPersMed Study (Biomarkers of Personalised Medicine) is a single-centre prospective observational cohort study with repetitive examination of participants in 2-year intervals. The aim is to evaluate the predictive impact of various traditional and novel biomarkers of cardiovascular, endocrine and metabolic pathways in asymptomatic individuals at risk for cardiovascular and/or metabolic disease.ParticipantsBetween 2010 and 2016, we recruited 1022 regional individuals into the study. Subjects aged 45 years or older presenting with at least one traditional cardiovascular risk factor or manifest type 2 diabetes mellitus (T2DM) were enrolled. The mean age of the participants was 57±8 years, 55% were female, 18% had T2DM, 33% suffered from arterial hypertension, 15% were smokers, 42% had hyperlipidaemia, and only 26% were at low cardiovascular risk according to the Framingham ‘Systematic COronary Risk Evaluation’.Findings to dateStudy procedures during screening and follow-up visits included a physical examination and comprehensive cardiovascular, endocrine, metabolic, ocular and laboratory workup with biobanking of blood and urine samples. The variety of assessed biomarkers allows a full phenotyping of individuals at cardiovascular and metabolic risk. Preliminary data from the cohort and relevant biomarker analyses were already used as control population for genomic studies in local and international research cooperation.Future plansParticipants will undergo comprehensive cardiovascular, endocrine and metabolic examinations for the next decades and clinical outcomes will be adjudicated prospectively.
Sarcopenia is linked with increased risk of falls, osteoporosis and mortality. No consensus exists about a gold standard “dual-energy X-ray absorptiometry (DXA) index for muscle mass determination” in sarcopenia diagnosis. Thus, many indices exist, but data on sarcopenia diagnosis agreement are scarce. Regarding sarcopenia diagnosis reliability, the impact of influencing factors on sarcopenia prevalence, diagnosis agreement and reliability are almost completely missing. For nine DXA-derived muscle mass indices, we aimed to evaluate sarcopenia prevalence, diagnosis agreement and diagnosis reliability, and investigate the effects of underlying parameters, presence or type of adjustment and cut-off values on all three outcomes. The indices were analysed in the BioPersMed cohort (58 ± 9 years), including 1022 asymptomatic subjects at moderate cardiovascular risk. DXA data from 792 baselines and 684 follow-up measurements (for diagnosis agreement and reliability determination) were available. Depending on the index and cut-off values, sarcopenia prevalence varied from 0.6 to 36.3%. Height-adjusted parameters, independent of underlying parameters, showed a relatively high level of diagnosis agreement, whereas unadjusted and adjusted indices showed low diagnosis agreement. The adjustment type defines which individuals are recognised as sarcopenic in terms of BMI and sex. The investigated indices showed comparable diagnosis reliability in follow-up examinations
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.