The canine-and-canine retainer displayed an 18% detachment rate, a value significantly lower than the 29% determined for the 0.0195" canine-to-canine retainers. The 0.0215" canine-to-canine retainer had the highest detachment rate (53%). The 37% detachment rate with dry field bonding was slightly higher than the 32% with relatively dry field bonding. Comparison of the composites showed a significantly higher detachment rate for Heliosit (73%) than for Concise (27%). Plaque accumulation increased with all retainer types in the course of the study, but with no significant inter-group differences. Tooth position with canine-to-canine retainers showed a good degree of stability. The canine-and-canine retainer induced frequent relapse of incisors not bonded to the retainer. In view of their higher rate of subjective discomfort, canine-and-canine retainers were given a significantly poorer rating than their canine-to-canine counterparts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.