The advent of new energy sources for hemostasis has greatly facilitated advanced laparoscopic procedures. We describe a straightforward technique of laparoscopic splenectomy (LS) accomplished using the THUNDERBEAT™ system (TS) (Olympus Medical Systems Corp., Tokyo, Japan) as the sole means of tissue dissection and hemostasis in two patients aged 19 and 6 years, respectively. The specimens were removed intact via a Pfannenstiel incision. Total operative time was 165 and 150 min, and length of hospital stay was three and 4 d, respectively. The TS is an appealing and reliable alternative to currently available energy devices, allowing fast dissection and secure hemostasis during laparoscopic splenectomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.