Electrical metal contacts to two-dimensional (2D) semiconducting transition metal dichalcogenides (TMDCs) are found to be the key bottleneck to the realization of high device performance due to strong Fermi level pinning and high contact resistances (R). Until now, Fermi level pinning of monolayer TMDCs has been reported only theoretically, although that of bulk TMDCs has been reported experimentally. Here, we report the experimental study on Fermi level pinning of monolayer MoS and MoTe by interpreting the thermionic emission results. We also quantitatively compared our results with the theoretical simulation results of the monolayer structure as well as the experimental results of the bulk structure. We measured the pinning factor S to be 0.11 and -0.07 for monolayer MoS and MoTe, respectively, suggesting a much stronger Fermi level pinning effect, a Schottky barrier height (SBH) lower than that by theoretical prediction, and interestingly similar pinning energy levels between monolayer and bulk MoS. Our results further imply that metal work functions have very little influence on contact properties of 2D-material-based devices. Moreover, we found that R is exponentially proportional to SBH, and these processing parameters can be controlled sensitively upon chemical doping into the 2D materials. These findings provide a practical guideline for depinning Fermi level at the 2D interfaces so that polarity control of TMDC-based semiconductors can be achieved efficiently.
Diverse diode characteristics were observed in two-dimensional (2D) black phosphorus (BP) and molybdenum disulfide (MoS) heterojunctions. The characteristics of a backward rectifying diode, a Zener diode, and a forward rectifying diode were obtained from the heterojunction through thickness modulation of the BP flake or back gate modulation. Moreover, a tunnel diode with a precursor to negative differential resistance can be realized by applying dual gating with a solid polymer electrolyte layer as a top gate dielectric material. Interestingly, a steep subthreshold swing of 55 mV/dec was achieved in a top-gated 2D BP-MoS junction. Our simple device architecture and chemical doping-free processing guaranteed the device quality. This work helps us understand the fundamentals of tunneling in 2D semiconductor heterostructures and shows great potential in future applications in integrated low-power circuits.
The present study was performed in order to examine the composition of the connective tissue that forms an attachment to a dental implant. 6 beagle dogs were used. All mandibular premolars were extracted. After 3 months of healing, 6 fixtures--3 in each side of the mandible--(Astra Tech Implants, Dental System TiO blast; Astra Tech AB, Mölndal, Sweden) were installed. After another 3 months of healing, abutment (Uni-abutment 45; Astra Tech AB, Mölndal, Sweden) connection was performed and a plaque control program was initiated. The animals were sacrificed and perfused with a fixative through the carotid arteries. Each implant site, including the implant and the soft and hard peri-implant tissues, was dissected, decalcified in EDTA and further processed using a "fracture technique". The specimens were subsequently embedded in EPON, cut with the microtome set at 3 microm and the sections stained in PAS and toluidine blue. From the EPON-embedded blocks, ultra-thin sections were cut and electron micrographs were prepared. The detailed histologic and morphometrical examinations were restricted to a 200 microm wide zone of connective tissue interposed between the apical border of the junctional epithelium and the bone tissue. In the analysis, this zone was further subdivided into 2 different units; (i) one central, 40 microm wide unit (zone A) located immediately next to the implant surface, and (ii) one lateral, 160 microm wide unit (zone B) that was continuous with the central unit. The implant surface apical of the junctional epithelium and coronal of the bone crest appeared to be in direct contact with a connective tissue. Zone A of this connective tissue was characterized by its (i) absence of blood vessels and (ii) abundance of fibroblasts which were interposed between thin collagen fibers. The more lateral zone B contained comparatively fewer fibroblasts, but more collagen fibers and blood vessels. There are reasons to assume that the fibroblast rich barrier tissue next to the titanium surface plays a rôle in the maintenance of a proper seal between the oral environment and the peri-implant bone.
The present experiment was performed to study the peri-implant tissue response to non-submerged (1-stage) and initially submerged (2-stage) implant installation procedures. 6 beagle dogs were used. All mandibular premolars and the 1st, 2nd and 3rd maxillary premolars were extracted. After 3 months of healing, 3 fixtures of the Astra Tech System were installed and submerged in the right (or the left) edentulous, premolar region in each of the 6 dogs. Radiographs were obtained immediately after fixture installation. In the radiographs, the distance between the abutment-fixture junction and the most "coronal" bone in contact with the implant surface was determined. 3 months later, abutments were connected to the initially submerged fixtures and another 3 fixtures of the same system were installed in the contralateral, edentulous premolar region. Abutments were, however, immediately connected to the newly-installed fixtures (non-submerged side; test side). The mucosal flaps were replaced, adjusted and sutured in such a way that the coronal portion of the abutments remained exposed in the oral cavity. A new set of radiographs were obtained from all 6 implant sites in each animal. A period of plaque control was initiated. Clinical examinations were performed and radiographs obtained from all implant sites after another 3 months and at the termination of the experiment. 9 months after the 1st fixture installation procedure, the animals were sacrificed, the mandibles were removed, and each implant region dissected. The most mesially-located implant sites were processed for ground sectioning. The remaining biopsies were processed and embedded in EPON. The histometric analysis included assessment of the vertical dimension of the marginal soft and mineralized peri-implant tissues. The ground sections were used for measurements describing (i) "bone to implant contact" and (ii) "bone density". It was observed that the mucosa and bone tissue that formed at implants placed in a non-submerged or a submerged procedure had many features in common. Thus, figures describing (i) the height of the mucosa, (ii) the length of the junctional epithelium and the height and quality of the zone of "connective tissue integration", (iii) the % of bone to implant contact as well as (iv) the density of the peri-implant bone, were similar in the submerged and the non-submerged groups. It is therefore suggested that a non-submerged (1-stage) installation technique may provide conditions for tissue integration that are similar to those obtained using a submerged (2-stage) approach.
Single-crystal metals have distinctive properties owing to the absence of grain boundaries and strong anisotropy. Commercial single-crystal metals are usually synthesized by bulk crystal growth or by deposition of thin films onto substrates, and they are expensive and small. We prepared extremely large single-crystal metal foils by “contact-free annealing” from commercial polycrystalline foils. The colossal grain growth (up to 32 square centimeters) is achieved by minimizing contact stresses, resulting in a preferred in-plane and out-of-plane crystal orientation, and is driven by surface energy minimization during the rotation of the crystal lattice followed by “consumption” of neighboring grains. Industrial-scale production of single-crystal metal foils is possible as a result of this discovery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.