Background
Sleep‐disordered breathing (SDB), defined as any difficulty in breathing during sleep, occurs in brachycephalic dogs. Diagnostic methods for SDB in dogs require extensive equipment and laboratory assessment.
Objectives
To evaluate the usability of a portable neckband system for detection of SDB in dogs. We hypothesized that the neckband is a feasible method for evaluation of SDB and that brachycephaly predisposes to SDB.
Animals
Twenty‐four prospectively recruited client‐owned dogs: 12 brachycephalic dogs and 12 control dogs of mesocephalic or dolicocephalic breeds.
Methods
Prospective observational cross‐sectional study with convenience sampling. Recording was done over 1 night at each dog's home. The primary outcome measure was the obstructive Respiratory Event Index (OREI), which summarized the rate of obstructive SDB events per hour. Additionally, usability, duration of recording, and snore percentage were documented.
Results
Brachycephalic dogs had a significantly higher OREI value (Hodges‐Lehmann estimator for median difference = 3.5, 95% confidence interval [CI] 2.2‐6.8; P < .001) and snore percentage (Hodges‐Lehmann estimator = 34.2, 95% CI 13.6‐60.8; P < .001) than controls. A strong positive correlation between OREI and snore percentage was detected in all dogs (rs = .79, P < .001). The neckband system was easy to use.
Conclusions and Clinical Importance
Brachycephaly is associated with SDB. The neckband system is a feasible way of characterizing SDB in dogs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.