Individual anatomical features of the paranasal sinuses and dentoalveolar system, the complexity of physiological and pathophysiological processes in this area, and the absence of actual standards of the norm and typical pathologies lead to the fact that differential diagnosis and assessment of the severity of the course of odontogenic sinusitis significantly depend on the measurement methods of significant indicators and have significant variability. Therefore, an urgent task is to expand the diagnostic capabilities of existing research methods, study the significance of the measured indicators, and substantiate the expediency of their use in the diagnosis of specific pathologies in an automated mode. Methods of digital filtering, image segmentation and analysis, fluid dynamics, and statistical and discriminant analysis were used. Preliminary differential diagnosis of odontogenic sinusitis can be performed by densitemetric analysis of tomographic images of the maxillary sinuses, performed using frontal multiplanar reconstructions according to a given algorithm. The very manifestation of the characteristic changes in the densitography of the maxillary sinus allows for the initiation of certain pathological processes and permits the development of the effectiveness of the diagnosis of the pathology of the sinus sinuses, which can be realized automatically in real life.
This study analyzes the existing methods for studying nasal breathing. The aspects of verifying the results of rhinomanometric diagnostics according to the data of spiral computed tomography are considered, and the methodological features of dynamic posterior active rhinomanometry and the main indicators of respiration are also analyzed. The possibilities of testing respiratory olfactory disorders are considered, the analysis of errors in rhinomanometric measurements is carried out. In the conclusions, practical recommendations are given that have been developed for the design and operation of tools for functional diagnostics of nasal breathing disorders. It is advisable, according to the data of dynamic rhinomanometry, to assess the functioning of the nasal valve by the shape of the air flow rate signals during forced breathing and the structures of the soft palate by the residual nasopharyngeal pressure drop. It is imperative to take into account not only the maximum coefficient of aerodynamic nose drag, but also the values of the pressure drop and air flow rate in the area of transition to the turbulent quadratic flow regime. From the point of view of the physiology of the nasal response, it is necessary to look at the dynamic change to the current mode, given the hour of the forced response, so that it will ensure the maximum possible acidity in the legend. When planning functional rhinosurgical operations, it is necessary to apply the calculation method using computed tomography, which makes it possible to predict the functional result of surgery.
Olfactory studies can be a criterion for evaluating rhinosurgical intervention, and olfactory impairment may indicate respiratory impairment. Therefore, the urgent task is to develop an integrated approach to determining respiratory and olfactory disorders. A structural scheme was developed for the method of objective diagnosis of respiratory and olfactory disorders, taking into account the measu, rement of both the aerodynamic parameters of nasal breathing and the calculation of energy characteristics, which are used to determine olfactory sensitivity. The diagnostic significance of the proposed method of analyzing rhinofolipometry data with regard to additional parameters was assessed - it is necessary to take into account the time and power of breathing when the threshold of sensation of the odorivector is at the transition point of the airflow mode to the turbulent quadratic. It has been established that it is advisable to use the energy criteria of nasal breathing, pneumatic power and energy of nasal breathing under the action of the corresponding odor vector for the assessment of respiratory impaired olfactory. To assess the respiratory impairment of olfactory, it is necessary to use the method in which an odor vector is installed in the air path of the rhinomanometer, and the patient is asked to perform breathing maneuvers with a consistent increase in respiration rate while fixing the time at which olfactory sensitivity is achieved and then determining the respiratory energy characteristics. A statistical processing of diagnostic results was carried out, which confirms the adequacy of the model of independent statistical verification and makes it possible to use this method for the functional diagnosis of respiratory-olfactory disorders and testing of respiratory-olfactory sensitivity. The probability index of the error of the second kind is 0.17.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.