The aim of the study is to determine physical and structural properties of woven synthetic prostheses depending on the type of the weave.Materials and Methods. Ten vascular prostheses manufactured at the Science and Technology Park of the BNTU "Polytechnic" (Minsk, Republic of Belarus) have been analyzed. The prostheses differed in the type of weaving, duration and temperature of thermal fixation during crimping. Three samples had a single-layer structure and 7 samples had a double-layer structure. Tests for water permeability, resistance to radial bending, and porosity of the prostheses have been performed.Results. The single-layer woven prostheses have demonstrated a low level of water permeability: the best result was shown by sample No.1: 80 [77.1; 80.5] ml/min/cm 2 . A strong direct correlation was revealed for these prostheses: the larger the pore diameter, the greater permeability (r=0.778; p=0.05). The single-layer woven prostheses appeared to be most resistant to radial bending, samples No.1 and 3 had no deformations at the minimum radius of the cylinder (R<4 mm), sample No.2 showed deformation on the cylinder with R=5 mm. For the single-layer prostheses, a strong negative correlation was noted (r=-0.97; p=0.04) between the density of the warp threads and the kinking radius.All double-layer prostheses have demonstrated higher water permeability and weak resistance to deformation during radial bending. Samples No.4 and 8 were found to have minimum and maximum water permeability of 276.5 [258.3; 288.4] and 538.8 [533.3; 564.3] ml/min/cm 2 , respectively. The minimum kinking radius (7 mm) was shown by samples No.9 and 10. The worst results were demonstrated by sample No.6, which was deformed with minimal bending.Conclusion. Samples with ordinary plain weave have a low level of water permeability and high resistance to radial deformation, which makes them look most promising for the application in vascular surgery.
The aim of the investigation was to study the factors influencing the radial stiffness of the thoracic aorta stent-grafts with the stent elements made of nitinol tubes by laser cutting and thermal shape setting. Materials and Methods. The work used stent elements made by different technologies by two different manufacturers from a nitinol tube with a wall thickness of 0.5 mm (E1) and 0.4 mm (E2), with a final diameter of 20 mm. Height of cells E1-15 mm, E2-12.5 mm. The stents were manually attached to a tubular woven non-crimped base (PTGO Sever, Russia) with a 6/0 suture, resulting in either single or continuous stitches. In the RLU124 radial force tester (Blockwise Engineering LLC, USA), each of the four stent-grafts, as well as their individual stent elements, were compressed by 10 mm from the initial diameter. The dependence of the radial forces on deformation under loading and unloading was graphically presented. The temperature and enthalpy of phase transitions of nitinols into the austenite (Af) and martensitic (Mf) phases were studied using differential scanning calorimetry (DSC-3; Mettler Toledo, USA). All indicators were compared with the characteristics of two commercial models-Cronus (China) and E-vita Open Plus (Germany). Results. Four prototypes of SibHybrid stent-grafts were tested; those differed in their stent elements, distances between them, and the type of sutures (single or continuous). The stent elements of the models studied differed in the values of Af, Mf, and the enthalpy of phase transitions of nitinols. The hardest stent was the E2 prototype. The fixation of stent elements to the woven fabric in the graft increased the radial force by 4.0-5.5 times. During compression by 50 and 20% of the original diameter, the SibHybrid models developed radial force 4.5-6.0 times greater compared with the E-vita Оpen Plus model. The radial force values of SibHybrid models were almost the same as for the Cronus and models at 20% compression. Using continuous twining round suturing increased the radial force by about 10 N; accordingly, SibHybrid E2 had the highest radial force because it was fixed by a continuous suture. The density of the stent elements fixed on the fabric did not affect the radial force of the stent-graft as a whole. Conclusion. In the manufacture of stent elements from nitinol tubes, the main factor determining the radial stiffness is the technology of nitinol shape setting. With the standard technology of thermal shape setting, radial force can be changed by varying the height of the structure cell element and the cross-sectional area of the cell bars, as well as the suturing technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.