Objective
Pharmaceutical intervention targets arm flexor spasticity with an often-unsuccessful goal of improving function. Flexion synergy is a related motor impairment that may be inadvertently neglected. Here, flexor spasticity and flexion synergy are disentangled to determine their contributions to reaching dysfunction.
Methods
Twenty-six individuals participated. A robotic device systematically modulated shoulder abduction loading during ballistic reaching. Elbow muscle electromyography data were partitioned into windows delineated by elbow joint velocity allowing for the separation of synergy- and spasticity-related activation.
Results
Reaching velocity decreased with abduction loading (p<0.001) such that velocity was 30% slower when lifting the arm at 50% of abduction strength compared to when arm weight was supported. Abnormal flexion synergy increased with abduction loading (p<0.001) such that normalized activation ranged from a median (interquartile range) of 0.07 (0.03–0.12) when arm weight was supported to 0.19 (0.12–0.40) when actively lifting (large effect size, d=0.59). Flexor spasticity was detected during reaching (p=0.016) but only when arm weight was supported (intermediate effect size, d=0.33).
Conclusion
Flexion synergy is the predominant contributor to reaching dysfunction while flexor spasticity appears only relevant during unnaturally occurring passively supported movement.
Significance
Interventions targeting flexion synergy should be leveraged in future stroke recovery trials.
To maintain upright posture and prevent falling, balance control involves the complex interaction between nervous, muscular and sensory systems, such as sensory reweighting. When balance is impaired, compliant foam mats are used in training methods to improve balance control. However, the effect of the compliance of these foam mats on sensory reweighting remains unclear. In this study, eleven healthy subjects maintained standing balance with their eyes open while continuous support surface (SS) rotations disturbed the proprioception of the ankles. Multisine disturbance torques were applied in 9 trials; three levels of SS compliance, combined with three levels of desired SS rotation amplitude. Two trials were repeated with eyes closed. The corrective ankle torques, in response to the SS rotations, were assessed in frequency response functions (FRF). Lower frequency magnitudes (LFM) were calculated by averaging the FRF magnitudes in a lower frequency window, representative for sensory reweighting. Results showed that increasing the SS rotation amplitude leads to a decrease in LFM. In addition there was an interaction effect; the decrease in LFM by increasing the SS rotation amplitude was less when the SS was more compliant. Trials with eyes closed had a larger LFM compared to trials with eyes open. We can conclude that when balance control is trained using foam mats, two different effects should be kept in mind. An increase in SS compliance has a known effect causing larger SS rotations and therefore greater down weighting of proprioceptive information. However, SS compliance itself influences the sensitivity of sensory reweighting to changes in SS rotation amplitude with relatively less reweighting occurring on more compliant surfaces as SS amplitude changes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.