This is to report the technique of reversed iliac leg stent-graft in endovascular treatment for isolated internal iliac artery (IIA) aneurysm, which had significant size discrepancy between the common iliac artery (CIA) and external iliac artery (EIA) in 3 patients from different hospitals. Three patients were a 85- and two 82-year-old men. Treated were right IIA aneurysms, sized 6.5×6.2 cm, 5.0×4.0 cm, and 4.1 cm in longest diameter, respectively. The diameters of the right CIA and right EIA measured 21 mm/11 mm, 15 mm/11 mm, and 20 mm/10 mm, respectively. In all cases, reversed iliac leg stent-grafts were prepared on-site; unsheathed and mounted upside-down manually, and deployed in each right CIA. Post-stent-graft angiograms showed complete exclusion of the aneurysms, except for minimal type 1 endoleak in one case. This technique is a useful treatment option in patients with isolated IIA aneurysm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.