BackgroundDelirium after cardiac surgery is associated with serious long-term negative outcomes and high costs. The aim of this study is to evaluate neurobehavioral, hemodynamic, and sedative characteristics of dexmedetomidine, compared with the current postoperative sedative protocol (remifentanil) in patients undergoing open heart surgery with cardiopulmonary bypass (CPB).MethodsOne hundred and forty two eligible patients who underwent cardiac surgery on CPB between April 2012 and March 2013 were randomly divided into two groups. Patients received either dexmedetomidine (range, 0.2 to 0.8 μg/kg/hr; n=67) or remifentanil (range, 1,000 to 2,500 μg/hr, n=75). The primary end point was the prevalence of delirium estimated daily via the confusion assessment method for intensive care.ResultsWhen the delirium incidence was compared with the dexmedetomidine group (6 of 67 patients, 8.96%) and the remifentanil group (17 of 75 patients, 22.67%) it was found to be significantly less in the dexmedetomidine group (p<0.05). There were no statistically significant differences between two groups in the extubation time, ICU stay, total hospital stay, and other postoperative complications including hemodynamic side effects.ConclusionThis preliminary study suggests that dexmedetomidine as a postoperative sedative agent is as sociated with significantly lower rates of delirium after cardiac surgery.
Branching angles and branch diameters were measured in a total of 850 arterial junctions in the coronary networks of two human hearts. Comparison is made with similar data obtained previously from the coronary networks of rats, and with what is considered to be optimum on theoretical grounds. It is concluded that the branching characteristics of the human coronary arteries are closer to the theoretical optimum than those of the coronary networks of rats. While the human data exhibit some departure from optimality and a good amount of scatter, these are well within levels observed elsewhere in the cardiovascular systems of man and animals, and considerably better than those found in the coronary networks of rats. The departure from optimality, in terms of physiological cost to the system, is within 5% for most data points.
Combined dual-source coronary CTA and CT MPI provides incremental diagnostic value compared with dual-source coronary CTA alone for the detection of significant coronary stenoses.
Killian-Jamieson diverticulum is a rare diverticular disease. This disease differs from Zenker's diverticulum in its location and mechanism. Various treatment modality have been attempted, but traditional surgical treatment has been recommended for a symptomatic Killian-Jamieson diverticulum due to the concern of possible nerve injury. We performed surgical treatment by cervical incision. We report here on a case of Killian-Jamieson diverticulum and we briefly review the relevant literature.
The results of this study suggest that ultrasonography may be a useful imaging method for detecting costal cartilage fractures overlooked on conventional radiographs and computed tomography in patients with minor blunt chest trauma. Early ultrasonographic evaluation can give more accurate information than clinical and radiologic evaluation in detecting costal cartilage fractures and sternal fractures that are overlooked on conventional radiography and computed tomography after minor blunt chest trauma.
Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.
The Jarvik 2000 axial flow left ventricular assist device (LVAD) is used clinically as a bridge to transplantation or as destination therapy in end-stage heart disease. The effect of the pump's continuous flow output on myocardial and end-organ blood flow has not been studied experimentally. To address this, the Jarvik 2000 pump was implanted in eight calves and then operated at speeds ranging from 8,000 to 12,000 rpm. Micromanometry, echocardiography, and blood oxygenation measurements were used to assess changes in hemodynamics, cardiac dimensions, and myocardial metabolism, respectively, at different speeds as compared with baseline (pump off, 0 rpm) in this experimental model. Microsphere studies were performed to assess the effects on heart, kidney, and brain perfusion at different speeds. The Jarvik 2000 pump unloaded the left ventricle and reduced end-diastolic pressures and left ventricular dimensions, particularly at higher pump speeds. The ratio of myocardial oxygen consumption to coronary blood flow and the ratio of subendocardial to subepicardial blood flow remained constant. Optimal adjustment of pump speed and volume status allowed opening of the aortic valve and contribution of the native left ventricle to cardiac output, even at the maximum pump speed. Neither brain nor kidney microcirculation was adversely affected at any pump speed. We conclude that the Jarvik 2000 pump adequately unloads the left ventricle without compromising myocardial metabolism or end-organ perfusion.
Endovenous laser ablation with a 980-nm laser wavelength is an easy and safe procedure in incompetent SSVs. After successful treatment, there is a very low rate of recanalisation of the SSV, which suggests that the procedure will provide lasting results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.