A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.
Benz[j]aceanthrylene (B[j]A) is a cyclopenta-fused polycyclic aromatic hydrocarbon with strong mutagenic and carcinogenic effects. We have identified B[j]A in air particulate matter (PM) in samples collected in Stockholm, Sweden and in Limeira, Brazil using LC-GC/MS analysis. Determined concentrations ranged between 1.57 and 12.7 and 19.6-30.2 pg/m(3) in Stockholm and Limeira, respectively, which was 11-30 times less than benzo[a]pyrene (B[a]P) concentrations. Activation of the DNA damage response was evaluated after exposure to B[j]A in HepG2 cells in comparison to B[a]P. We found that significantly lower concentrations of B[j]A were needed for an effect on cell viability compared to B[a]P, and equimolar exposure resulted in significant more DNA damage with B[j]A. Additionally, levels of γH2AX, pChk1, p53, pp53, and p21 proteins were higher in response to B[j]A than B[a]P. On the basis of dose response induction of pChk1 and γH2AX, B[j]A potency was 12.5- and 33.3-fold higher than B[a]P, respectively. Although B[j]A levels in air were low, including B[j]A in the estimation of excess lifetime cancer risk increased the risk up to 2-fold depending on which potency factor for B[j]A was applied. Together, our results show that B[j]A could be an important contributor to the cancer risk of air PM.
Complex mixtures of polycyclic aromatic hydrocarbons (PAHs) are common environmental pollutants associated with adverse human health effects including cancer. However, the risk of exposure to mixtures is difficult to estimate, and risk assessment by whole mixture potency evaluations has been suggested. To facilitate this, reliable in vitro based testing systems are necessary. Here, we investigated if activation of DNA damage signaling in vitro could be an endpoint for developing whole mixture potency factors (MPFs) for airborne PAHs. Activation of DNA damage signaling was assessed by phosphorylation of Chk1 and H2AX using Western blotting. To validate the in vitro approach, potency factors were determined for seven individual PAHs which were in very good agreement with established potency factors based on cancer data in vivo. Applying the method using Stockholm air PAH samples indicated MPFs with orders of magnitude higher carcinogenic potency than predicted by established in vivo-based potency factors. Applying the MPFs in cancer risk assessment suggested that 45.4 (6% of all) cancer cases per year in Stockholm are due to airborne PAHs. Applying established models resulted in <1 cancer case per year, which is far from expected levels. We conclude that our in vitro based approach for establishing MPFs could be a novel method to assess whole mixture samples of airborne PAHs to improve health risk assessment.
The Salmonella/microsome assay is the most used assay for the evaluation of air particulate matter (PM) mutagenicity and a positive correlation between strain TA98 responses and benzo[a]pyrene (B[a]P) levels in PM has been found. However, it seems that the major causes of PM mutagenicity in this assay are the nitro and oxy-PAHs. Salmonella YG5161, a 30-times more responsive strain to B[a]P has been developed. To verify if YG5161 strain was sufficiently sensitive to detect mutagenicity associated with B[a]P mutagenicity, PM samples were collected in Brazil and Sweden, extracted with toluene and tested in the Salmonella/microsome microsuspension assay. PAHs and B[a]P were determined and the extracts were tested with YG5161 and its parental strain TA1538. The extracts were also tested with YG1041 and its parental strain TA98. For sensitivity comparisons, we tested B[a]P and 1-nitropyrene (1-NP) using the same conditions. The minimal effective dose of B[a]P was 155 ng/plate for TA1538 and 7 ng/plate for YG5161. Although the maximum tested dose, 10 m(3) /plate containing 9 ng of B[a]P in the case of Brazilian sample, was sufficient to elicit a response in YG5161, mutagenicity was detected at a dose as low as 1 m(3) /plate (0.9 ng). This is probably caused by nitro-compounds that have been shown to be even more potent than B[a]P for YG5161. It seems that the mutagenicity of B[a]P present in PM is not detectable even with the use of YG5161 unless more efficient separation to remove the nitro-compounds from the PAH extract is performed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.