In order to obtain the seismic dynamic characteristics of a shallow-bias tunnel with a small space, a series of large-scale shaking table model tests were carried out. The key technology of the test is introduced in detail, for example, similar ratios of model, test equipment, testing model box, testing model, sensor arrangement, seismic waves, and testing system. The results show that the first predominant frequency is similar between measuring points. However, the second predominant frequency is highly different between measuring points. The first and second predominant frequencies gradually decrease with the increasing of input PGA. The rock stratum can shield seismic wave in the high frequency band. The research results provide reference for similar tunnels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.